SAFETY WARNINGS FOR THE APPLIANCES
USING R290 COOLING FLUID (PROPANE) - R600a
COOLING FLUID (ISOBUTANE)
Isobutane and propane are natural gases without effects
on the environment, but inflammable.
It is therefore essential to ensure that all refrigerant pipes are not damaged
before connecting the appliance to the mains supply.
Every 8 gr. of refrigerant, the installation room must have a 1 m³
minimum volume.
The amount of refrigerant of the appliance is indicated on the rating
plate of the device.
In the event of leakage of the refrigerant, avoid using open flames or
sources of ignition in the vicinity of the area of the leak.
Be careful not to not damage the refrigerant circuit pipes during
positioning, installation and cleaning.
Avoid using naked flames or sparks inside the appliance.
Warning! Do not damage the refrigerant circuit.
Warning! Do not damage the inner or outer walls of the appliance: the
refrigerant fluid circuit may be damaged. In case of damage to the walls,
do not start the appliance and contact a qualified service technician.
Warning! In case of damage to the refrigerant fluid circuit, do not start
the appliance and contact a qualified service technician.
Warning! Keep the ventilation openings in the appliance casing or in
the recessed structure clear of obstructions.
Warning! Do not use electrical appliances inside the compartments of
the appliance for storing frozen foods if these are not those recommended
by the manufacturer.
Warning! Do not store explosive substences such as aerosol cans with
flammable propellant in this aplliance.