4.10.4

Switch position indicator

Note
Please study the illustration of the switch position indicator in the diagram below before you
assemble the cable-operated switch.
①②③ = Position indication window of the pretensioned wire
① Wire is correctly tensioned, cable-operated switch is operational.
② Arrow in the reset position. Wire must be tensioned until the indicator arrow is in position
①.
③ Wire is overtensioned, cable-operated switch is not operational. The LED lamp ④ is
illuminated red. If the switch does not move automatically to position ② , press the blue reset
button ⑤ in order to release the switch.