Setup Of A Safety Function - Siemens SIRIUS Configuration Manual

Cable-operated switches and foot switches
Hide thumbs Also See for SIRIUS:
Table of Contents

Advertisement

Cable-operated switches
4.11 Application examples for cable-operated switches
4.11.3

Setup of a safety function

Setup of a safety function
A safety chain normally comprises the following functions: sensing, evaluating and
responding. In detail this means:
• Detect = the detection of a safety requirement with corresponding sensors, e.g. SIRIUS
cable-operated switches or position switches
• Evaluate = the detection of a safety requirement and the reliable initiation of a reaction,
e.g. shutting down the enabling circuits
• React = shutting down the hazard through suitable motor switching devices such as
contactors, fail-safe motor starters, or fail-safe soft starters
Figure 4-1
30
Possible setup of a safety function with SIRIUS cable-operated switches
Cable-operated switches and foot switches
Configuration Manual, 09/2020, A5E43902195002A/RS-AA/001