Specifications - SEPLOS PUSUNG 2 User Manual

Table of Contents

Advertisement

SEPLOS PUSUNG 2
ND
GENERATION 51.2V 100AH LIFEPO4 BATTERY PACK USER MANUAL
 BMS has over-discharge, over-charge, over-current, high and low temperature warning and
protection functions.
 BMS monitors charge and discharge state, and balance current and voltage of each cell.
 BMS comes with upper computer system for real-time cell and pack voltage, current,
temperature, and battery status monitoring and recording.
Flexible configuration, max. 15 packs can be connected in parallel for expanding capacity and
power with 8 DIP switches.
Working temperature range is from -20℃~50℃ (Charging 0℃~50℃; discharging -20℃~50℃
with excellent discharge performance and cycle life.

2.2 Specifications

Basic Parameters
Nominal Voltage (V)
Nominal Capacity (Ah)
Nominal Power (Wh)
Dimension (mm)
Weight (Kg)
Discharge Cut-off Voltage (V)
Charge Voltage (V)
Max. Charge/Discharge Current (A)
Communication Interface
Configuration
Working Temperature
Cell chemistry
Cycle life
IP level
565*440*170mm
CAN,RS485
0~50℃(Charge)
-20~50℃(Discharge)
-20~55℃(Storage)
Lithium iron phosphate (LiFePO4)
≥80% capacity state after 4800
cycles at 0.5C, 25℃, 100% DOD
4
www.seplos.com
PUSUNG
51.2V
100Ah
5.12KWh
56.2KG
41.6V
54.5V
100A
16S1P
IP 20
)