SEPLOS PUSUNG 2
ND
GENERATION 51.2V 100AH LIFEPO4 BATTERY PACK USER MANUAL
The real capacity of each single cell is 105Ah.
The module inside comes with 16 cells in parallel. And the default setting of BMS pack
discharge end voltage is for 15 cells in parallel.
2.5 Advanced Battery Management System (BMS)
The BMS is applied to monitor current, voltage, temperature, protection against over-charge,
over-discharge, over-current, over-temperature, under-temperature and short circuit. The BMS
provides cell balancing and current limitation during charging process to ensure a reliable safety
and performance.
2.5.1 BMS Functions
Over charge protection
Over discharge protection
Over current protection
Cell balancing
Temperature protection
11