2. Select the correct charging mode by repeatedly pressing the
mode button (A) until the resp. LED for the correct charging
mode (1 - 6) lights up. By pressing the mode button repeatedly,
the charger turns to the next charging mode.
Now the battery charging state LED (G) lights up.

Battery Charging State

Flash
OFF
ON
Flash
ON
ON
ON
ON
ON
ON
Diagnosis
and Recovery
Charging
FULL
OFF
OFF
OFF
OFF
Flash
OFF
ON
Flash
ON
ON
The diagnostic function automatically checks
battery status and detects the voltage.
Charging to 80% of the energy
1) Charging with high rate: Charger delivers
constant current of 7 A until the voltage reaches
to 12.8 V resp. a current of 3.5 A is delivered until
the voltage reaches 25.6 V.
2) Charging with medium rate: Charger delivers
constant current of 5 A (drops to 3 A) until the
voltage reaches to 14.1 V resp. a current of 3 A
is delivered until the voltage reaches 28.2 V.
Using
Charging
Status
Below 25%
Below 50%
Below 75%
Below
100%
Fully
charged
26
Charging
Phase
Diagnosis &
Recovery
Bulk Charge 1
Bulk Charge 2
Absorption
Trickle /
Maintenance