Troubleshooting Guide - Hunter Solar Sync Owner's Manual

Wired and wireless
Hide thumbs Also See for Solar Sync:
Table of Contents

Advertisement

Troubleshooting Guide

Problem
Controller shows
• Wires not properly connected
"NO SS" in display
Seasonal Adjustment
• Region is too high
too low
• Water Adjustment setting
• Location of sensor does not
Seasonal Adjustment
• Region is too low
too high
• Water Adjustment setting
Controller's Seasonal
• If using a wireless Solar Sync
Adjustment is reset
to 10% and does not
change
16
Cause
to controller terminals. Sensor
may not be installed.
is too low
allow for full sun
is too high
model, the communication has
been lost between the sensor
and receiver.
Solution
Check the connection between sensor/receiver and controller.
Make sure the controller dial is in the RUN position. Increase the
value on the Water Adjustment scale (10 is maximum). Once the
setting is changed, the controller will immediately be updated with
the new Seasonal Adjustment %. Increase the Water Adjustment
setting until the desired Seasonal Adjustment % is shown. If you max
out the Water Adjustment scale at 10 and still require more Seasonal
Adjustment, move down to the next lower Region (from Region 4 to 3,
for example).
Make sure the controller dial is in the RUN position. Decrease the
value on the Water Adjustment scale (default setting is 5). Once the
setting is changed, the controller will immediately be updated with
the new Seasonal Adjustment %. Decrease the Water Adjustment
setting until the desired Seasonal Adjustment % is shown. If you
minimize the Water Adjustment scale down to 1 and still require a
reduction in Seasonal Adjustment, move up the next Region (from
Region 2 to 3, for example).
Follow steps to readdress wireless sensor on page 13. Once
communication between wireless sensor and wireless receiver is
re-established, the percentage (%) will increase for normal operation.