TROUBLESHOOTING GUIDE ..........................................................................

PROBLEM
System Status Indicator
light is off
System Status Indicator
light is flashing red
System Status Indicator is
steady red
22
CAUSE
No AC power to the Flow-Clik
Interface Box
Irrigation system is in an overflow
condition
Irrigation system is in an overflow
condition
SOLUTION
A) Check that the Interface Box power leads (yellow wires) are
attached to the 24 VAC terminals on the controller.
B) Verify that the power to the controller is on.
Normal operation during an overflow condition. The Flow-Clik has
identified overflow condition and is waiting the pre-set startup
delay period before shutting the system off.
Normal operation during an overflow condition.
A) The Flow-Clik has identified an overflow condition and is
waiting the predetermined amount of time set as the Interrupt
Period before restarting the irrigation cycle.
B) The Interrupt Period setting is in the Manual Restart position
requiring that the Flow-Clik be reset before irrigation can resume.
Press the Restart System button to reactivate the Flow-Clik.