Stryker T/Pump Series Operation Manual

Stryker T/Pump Series Operation Manual

Localized temperature therapy system
Table of Contents

Advertisement

Available languages

Available languages

T/Pump® Series Localized Temperature Therapy
System
TP700
TP700C
Operations Manual
2017/10 E.1
101515 REV E
www.stryker.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T/Pump Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Stryker T/Pump Series

  • Page 1 T/Pump® Series Localized Temperature Therapy System TP700 TP700C Operations Manual 2017/10 E.1 101515 REV E www.stryker.com...
  • Page 2 sample text...
  • Page 3 Warning non-ionizing radiation Catalogue number Serial number Manufacturer For US Patents see www.stryker.com/patents Dangerous voltage Type BF applied part Medical Equipment Recognized by Underwriters Laboratories LLC With Respect to Electric Shock, Fire, and Mechanical Hazards only in accordance with UL 60601-1: 2003 and CAN/ CSA-C22.2 No.
  • Page 4 sample text...
  • Page 5: Table Of Contents

    Cleaning the water circuit and hoses ....................1-14 Preventive maintenance ........................1-15 Accessories ............................1-16 EMC Information ..........................1-18 Warranty ............................1-22 Warranty exclusion and damage limitations ..................1-22 Return authorization........................1-22 Damaged product........................... 1-22 International warranty clause ......................1-22 www.stryker.com 101515 REV E...
  • Page 6: Warning/Caution/Note Definition

    Note: Provides special information to make maintenance easier or important instructions clearer. 101515 REV E www.stryker.com...
  • Page 7: Summary Of Safety Precautions

    • Do not use the product next to or stacked with other equipment. If next to or stacked is necessary, observe the product to verify normal operation in the configuration in which it used. www.stryker.com 101515 REV E...
  • Page 8: Introduction

    Introduction English This manual assists you with the operation or maintenance of your Stryker product. Read this manual before operating or maintaining this product. Set methods and procedures to educate and train your staff on the safe operation or maintenance of this product.
  • Page 9: Contraindications

    Introduction English Contraindications Stryker promotes the assessment of each patient and appropriate usage by the operator. Contraindications for this product are for patients with the conditions specified below. Heating contraindications include: • Application to a body surface with compromised blood flow (Ischemia, area under pressure, arterial insufficiency) •...
  • Page 10: Product Illustration

    Environmental conditions 120°F 90°F (48°C) Ambient operating temperature (32.2°C) -20°F 60°F (-28°C) (15.6°C) Stryker reserves the right to change specifications without notice. Product illustration Handle vents Hose storage Keypad Cord storage Flow indicator Tethered open cap Warm or cool delivery Handle...
  • Page 11: Product Keypad

    Portage, MI 49002 To view your operations or maintenance manual online, see https://techweb.stryker.com/. Have the serial number (A) of your Stryker product available when calling Stryker Customer Service or Technical Support. Include the serial number in all written communication. www.stryker.com...
  • Page 12: Serial Number Location

    Introduction English Serial number location 101515 REV E www.stryker.com...
  • Page 13: Operation

    Figure 1-4: Twist fittings Figure 1-3: Connecting fittings After you insert fittings (Figure 1-5 on page 1-9), snap the lock ring into place (Figure 1-6 on page 1-9). Figure 1-6: Lock ring Figure 1-5: Insert fittings www.stryker.com 101515 REV E...
  • Page 14: Connecting And Disconnecting The Colder Connectors

    Open the clamp by pushing on the serrated end (Figure 1-9 on page 1-10). Figure 1-10: Close the clamp Figure 1-9: Open the clamp Close the clamp by pressing the clamp together (Figure 1-10 on page 1-10). 1-10 101515 REV E www.stryker.com...
  • Page 15: Starting The Pump

    10. Position the pump at or above the level of the pad. Note: Do not place the pump below the pads, water will drain into the pump during shut off. If the pump has been overfilled or if you connected multiple pads, excess water can leak. www.stryker.com 101515 REV E 1-11...
  • Page 16: Starting Therapy Cycles

    Note: To prevent water spillage, always raise the connections above the level of the pad and the pump before disconnecting the pad from the pump. Coil the hose and attach the Clik-Tite connectors together on the hose. Secure the hose to the pump by using the tube set strap. 1-12 101515 REV E www.stryker.com...
  • Page 17: Storing The Pump, Short Term

    Remove the fill cap and invert the pump over a sink to drain. Replace the fill cap after all of the fluid has drained from the hoses and reservoir. Connect the ends of the connector hoses together, where applicable. www.stryker.com 101515 REV E 1-13...
  • Page 18: Cleaning

    Press the On/Standby button to start the pump. Circulate the solution for one hour. Drain the solution from the reservoir. Rinse and drain the reservoir with water. 10. Dry the reservoir inside and outside with a dry, lint free cloth. 1-14 101515 REV E www.stryker.com...
  • Page 19: Preventive Maintenance

    Remove product from service before you perform the preventive maintenance inspection. Check all items listed during annual preventive maintenance for all Stryker Medical products. You may need to perform preventive maintenance checks more often based on your level of product usage. Service only by qualified personnel.
  • Page 20: Accessories

    Accessories English These accessories may be available for use with your product. Confirm availability for your configuration or region. Call Stryker Customer Service: 1-800-327-0770. Test tools Catalog Number Product Name Number in Carton TPT9 Measures the temperature and water flow...
  • Page 21 8002-062-622 22 in. (56 cm) 15 in. (38 cm) Non-woven Colder fabric on both connectors sides 8002-062-626 Colder 26 in. (66 cm) 18 in. (46 cm) Non-woven connectors fabric on both sides www.stryker.com 101515 REV E 1-17...
  • Page 22: Emc Information

    25 cycles for 25 cycles device be powered from an uninterrupted power supply <5% Ut (>95% dip in Ut) <5% Ut (>95% dip in Ut) or a battery. for 5 sec for 5 sec 1-18 101515 REV E www.stryker.com...
  • Page 23 The T/Pump system is suited for use in the electromagnetic environment specified below. The customer or the user of the T/Pump system should ensure that it is used in such an environment. Immunity Test Compliance Level Electromagnetic Environment - Guidance IEC 60601 Test Level www.stryker.com 101515 REV E 1-19...
  • Page 24 Guidance and Manufacturer’s declaration - Electromagnetic Emissions The T/Pump system is intended for use in an electromagnetic environment specified below. The customer or the user of the T/Pump system should ensure that it is used in such an environment. 1-20 101515 REV E www.stryker.com...
  • Page 25 Class B CISPR 11 supply network that supplies buildings used for domestic purposes. Harmonic Emissions Class A IEC 61000-3-2 * Voltage Fluctuations Complies Flicker Emissions IEC 61000-3-3 www.stryker.com 101515 REV E 1-21...
  • Page 26: Warranty

    Stryker will file a freight claim with the appropriate carrier for damages incurred. Claims will be limited in amount to the actual replacement cost. In the event that this information is not received by Stryker within the fifteen (15) day period following the delivery of the product, or the damage was not noted on the delivery receipt at the time of receipt, the customer will be responsible for payment of the original invoice in full within thirty (30) days of receipt.
  • Page 27 T/Pump® Système de thermothérapie localisée TP700 TP700C Manuel d’utilisation 2017/10 E.1 101515 REV E www.stryker.com...
  • Page 28 sample text...
  • Page 29 Avertissement ; rayonnement non ionisant Numéro de référence Numéro de série Fabricant Pour les brevets américains, consulter www.stryker.com/patents Tension dangereuse Pièce appliquée de type BF Équipement médical classé par Underwriters Laboratories LLC pour les risques d'électrocution, d'incendie et les risques mécaniques uniquement, conformément aux normes UL 60601-1: 2003 et CAN/CSA-C22.2 N°...
  • Page 30 sample text...
  • Page 31 Nettoyage du circuit d'eau et des tuyaux ..................... 2-14 Maintenance préventive......................... 2-15 Accessoires ............................2-16 Informations CEM..........................2-18 Garantie ............................. 2-22 Exclusion de garantie et limitations des dommages ................2-22 Autorisation de retour........................2-22 Produit endommagé........................2-22 Clause de garantie internationale ...................... 2-22 www.stryker.com 101515 REV E...
  • Page 32: Définition De " Avertissement ", " Mise En Garde " Et " Remarque

    à prendre afin d’assurer l’utilisation sûre et efficace du dispositif et d’éviter les dommages qui pourraient découler de l’usage ou du mésusage du matériel. Remarque : Fournit des informations spécifiques destinées à faciliter l’entretien ou à clarifier des instructions importantes. 101515 REV E www.stryker.com...
  • Page 33: Résumé Des Mesures De Sécurité

    Ne pas utiliser le produit à côté de, ou en superposition avec d’autres appareils. S’il doit être utilisé à côté de, ou en superposition avec d’autres appareils, observer le produit pour vérifier qu’il fonctionne normalement dans la configuration dans laquelle il sera utilisé. www.stryker.com 101515 REV E...
  • Page 34: Introduction

    Introduction Ce manuel vous aide à utiliser ou entretenir votre produit Stryker. Lire ce manuel avant d’utiliser ce produit ou d’en effectuer la maintenance. Il convient d'établir des procédures et techniques visant à éduquer et à former le personnel quant au fonctionnement et à l’entretien sécuritaires de ce produit.
  • Page 35: Contre-Indications

    Introduction Contre-indications Stryker recommande l’évaluation de chaque patient et une utilisation adaptée par l’opérateur. Les contre-indications pour ce produit s’appliquent aux patients qui présentent les états suivants : Les contre-indications au réchauffement comprennent : Français • Application sur une surface corporelle avec une circulation sanguine compromise (ischémie, zone sous pression, insuffisance artérielle)
  • Page 36: Illustration Du Produit

    Température ambiante de (48°C) (32.2°C) -20°F fonctionnement 60°F (-28°C) (15.6°C) Stryker se réserve le droit de modifier ces caractéristiques sans préavis. Illustration du produit Rangement du tuyau Trous d’aération de la poignée Clavier Rangement du cordon Indicateur de débit Capuchon ouvert captif Traitement chaud ou froid Poignée...
  • Page 37: Clavier Du Produit

    Pour consulter votre mode d'emploi ou votre manuel d'entretien en ligne, rendez-vous sur https://techweb.stryker.com/. Avoir le numéro de série (A) du produit Stryker à disposition avant d’appeler le service clientèle ou le support technique de Stryker. Inclure le numéro de série dans toutes les communications écrites.
  • Page 38: Emplacement Du Numéro De Série

    Introduction Emplacement du numéro de série Français 101515 REV E www.stryker.com...
  • Page 39: Fonctionnement

    Figure 2-3 : Connexion des raccords Quand les raccords sont introduits (Figure 2-5 à la page 2-9), enclencher l’anneau de blocage (Figure 2-6 à la page 2-9). Figure 2-6 : Anneau de blocage Figure 2-5 : Introduction des raccords www.stryker.com 101515 REV E...
  • Page 40: Connexion Et Déconnexion Des Connecteurs Colder

    Ouvrir la pince en pressant sur sa partie dentelée (Figure 2-9 à la page 2-10). Figure 2-10 : Fermeture de la pince Figure 2-9 : Ouverture de la pince Fermer la pince en pressant ses parties ensemble (Figure 2-10 à la page 2-10). 2-10 101515 REV E www.stryker.com...
  • Page 41: Démarrage De La Pompe

    Il faut environ 15 minutes pour atteindre la température d’eau sélectionnée. Le voyant à côté de la température sélectionnée s’arrête de clignoter. • Contrôler le niveau d’eau. Si le niveau d’eau baisse en-dessous du niveau de fonctionnement, ajouter de l’eau. Appliquer le Mul-T-Pad au patient en suivant les instructions du médecin. www.stryker.com 101515 REV E 2-11...
  • Page 42: Démarrage Des Cycles De Traitement

    Le voyant DEL de la durée de traitement s’arrête de clignoter et le voyant DEL de la valeur de consigne clignote. • Quand la valeur de consigne est atteinte, le voyant DEL rouge clignote avec un bref bip sonore pour informer l’opérateur du fait que le prochain cycle de traitement a démarré. 2-12 101515 REV E www.stryker.com...
  • Page 43: Arrêt De La Pompe

    Retirer le capuchon de remplissage et inverser la pompe au-dessus d’un évier pour la purger. Remettre le capuchon de remplissage en place une fois que tout le liquide est purgé des tuyaux et du réservoir. Connecter ensemble les extrémités des tuyaux de connexion, le cas échéant. www.stryker.com 101515 REV E 2-13...
  • Page 44: Nettoyage

    Appuyer sur le bouton Marche/veille pour démarrer la pompe. Laisser circuler la solution pendant une heure. Purger la solution du réservoir. Rincer et purger le réservoir avec de l’eau. 10. Sécher l'intérieur et l'extérieur du réservoir à l'aide d'un linge non pelucheux sec. 2-14 101515 REV E www.stryker.com...
  • Page 45: Maintenance Préventive

    Retirer le produit du service avant d’effectuer les vérifications de maintenance préventive. Vérifier tous les éléments mentionnés pendant l’entretien préventif annuel pour tous les produits Stryker Medical. Il peut être nécessaire d’effectuer les vérifications de maintenance préventive plus souvent en fonction de la fréquence d’utilisation du produit.
  • Page 46: Accessoires

    Accessoires Les accessoires suivants peuvent être disponibles pour le produit. Confirmer la disponibilité en fonction de la configuration du produit ou du pays. Contacter le service clientèle Stryker : +1-800-327-0770. Outils de test Numéro de référence Nom du produit Quantité dans la boîte Français...
  • Page 47 46 cm 33 cm Non tissé des Colder deux côtés Français 8002-062-622 56 cm 38 cm Connecteurs Non tissé des Colder deux côtés 8002-062-626 Connecteurs 66 cm 46 cm Non tissé des Colder deux côtés www.stryker.com 101515 REV E 2-17...
  • Page 48: Informations Cem

    à pendant 25 cycles pendant 25 cycles l’aide d’un onduleur ou d’une batterie. <5 % Ut (baisse >95 % en <5 % Ut (baisse >95 % en pendant 5 secondes pendant 5 secondes 2-18 101515 REV E www.stryker.com...
  • Page 49 À 80 MHz et 800 MHz, la distance de séparation pour la gamme de fréquences la plus élevée s'applique. Remarque : Ces directives peuvent ne pas convenir à toutes les situations. La propagation électromagnétique est affectée par l'absorption et la réflexion des structures, des objets et des personnes. www.stryker.com 101515 REV E 2-19...
  • Page 50 émetteurs RF fixes, telles que déterminées par une étude de site électromagnétique doivent être inférieures au niveau de conformité de chaque gamme de fréquences. Des interférences peuvent survenir à proximité des appareils porteurs du symbole suivant : 2-20 101515 REV E www.stryker.com...
  • Page 51 établissements domestiques et ceux directement Classe B CISPR 11 raccordés au réseau basse tension public alimentant les bâtiments à usage domestique. Émissions harmoniques Classe A IEC 61000-3-2 * Fluctuations de tension Émissions de scintillement Conforme IEC 61000-3-3 www.stryker.com 101515 REV E 2-21...
  • Page 52: Garantie

    Le montant des réclamations sera limité au coût de remplacement réel. Si cette information n'est pas reçue par Stryker dans les quinze (15) jours suivant la livraison du produit, ou si les dommages ne sont pas signalés sur le bordereau de livraison au moment de la réception, le client restera redevable du paiement intégral de la facture d'origine dans un délai de trente (30) jours à...
  • Page 54 Stryker Medical 3800 E. Centre Avenue Portage, MI 49002 2017/10 101515 REV E www.stryker.com...

This manual is also suitable for:

Tp700Tp700c

Table of Contents

Save PDF