Events Which Doesn't Require Maintenance - NEC Express5800 Notice

Ilo embedded server express report service
Hide thumbs Also See for Express5800:
Table of Contents

Advertisement

4.2. Events which doesn't require maintenance

Please check below table. Some SNMP Trap is combined with multiple IML. So, if any of the
combined IML is defined to send reports, the combined SNMP Trap became a report target. Then,
the SNMP Trap, generated by IML which doesn't require sending report, became a report target.
Three events in below table will be sent to Maintenance Company through Express Report Service
(MG), but these events doesn't require maintenance and the Maintenance Company will not access
to the customers.
IML
CLASS 0x2 CODE 0x1a
FAN Failure
CLASS 0x2 CODE 0x33
FAN Degraded
Table 4 Events which doesn't require maintenance
Default
CLASS
CODE
Severity
0x2
0x23
0x2
0x33
0xb
0x42
© NEC Corporation 2016
15
Table 3 Example
Express
SNMP
Report
Trap ID
Service
(Report is
required)
6035
×
(Report is not
required)
Caution
System Fans Not Redundant (Location %1)
Caution
Fan Degraded (Fan %1, Location %2)
Smart Storage Battery has exceeded the maximum amount of
Caution
devices supported (Battery %1, service information: 0x07)
Express Report Service (MG)
◎(Report Target)
SNMP Trap ID 6035 became and report
target of Express Report Service (MG),
because FAN Failure IML is an report target
of Express Report Service.
But, the SNMP Trap which is generated from
FAN Degraded IML has same SNMP Trap ID
6035, which Trap ID is a report target
combined with FAN Failure IML. So, the
SNMP Trap generated from FAN Degraded
IML became a report target in spite of it
doesn't require report.
Description

Advertisement

Table of Contents