NVT Phybridge EC4 Quick Start Manual

Long reach poe over coax

Advertisement

Quick Links

Long Reach PoE over Coax
Fast Ethernet and PoE++ (Up to 50W)
PN: NV-EC-04

EC4 Adapter Applications

The EC4 Adapter enables extended Ethernet and PoE reach beyond traditional distances
using coax infrastructure. When paired with the CLEER24 Switch, EC10 Switch or EC-Base
Extender, the Adapter delivers 100Mbps, symmetrical full duplex. The EC offering is
designed specifically to enable easy deployment over coax for reaches beyond that of
standard Ethernet eliminating the costs and disruption associated with IDF closet
requirements.
100 Mbps (full duplex, symmetrical) & PoE++ over Coax with 3,000ft (915m) reach.
NV-CLR-024/NV-EC-10
RUN
ALARM
FAULT
Reset
1
To Application
Standard PoE Switch
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
43
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
*Base Extender can be powered locally for use with non-PoE switches.
Technical Specifications
Model
Part Number
Dimensions
Weight
Interface: Network
Infrastructure side
(CLEER)
Interface: IEEE Side (IP
Device)
Power Supply
888.901.3633 | +44 (0) 208 977 6614
www.nvtphybridge.com
U P C : 7 3 5 8 9 0 5 0 0 0 7 0
EC4
• Paired with CLEER24, EC10 or EC-Base
• 1 uplink port and 4 downlink ports
• Up to 50W PoE per downlink port
• Local power option
GBE 1
1
3
5
7
9
GBE 2
POWER
2
4
6
8
10
1
3
5
7
9
11
13
15
17
19
21
23
2
4
6
8
10
12
14
16
18
20
22
24
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
NV-ECLK-BSE
EC-Base
45
47
SFP+1
SFP 1
Long Reach PoE over Coax
SFP+2
SFP 2
46
48
EC4
NV-EC-04
11cm x 7cm x 2.5cm (LxWxH);
4.3" x 2.75" x 0.98" (LxWxH)
96g (3.38oz.)
1 BNC port: Coax cable (RG59, RG6,
RG11)
4 RJ45 ports: devices must be IEEE 802.3
af/at compliant
PoE from the CLEER / EC switch, or
external power supply; maximum 50W
(over 4-pairs) each port
EC4
over Coax
(NV-EC-04)
Coax Cable
up to 3,000ft (915m)
Local Power Option
*
Coax Cable
up to 3,000ft (915m)
Local Power Option
DC IN
Power
Consumption
Operating
temperature
Mean Time
Before Failure
(MTBF)
Humidity
MADE IN CANADA
NV-EC-04
IP ENDPOINT
IP ENDPOINT
IP ENDPOINT
IP ENDPOINT
NV-EC-04
IP ENDPOINT
IP ENDPOINT
IP ENDPOINT
IP ENDPOINT
Optional (sold separately)
48V – 56VDC via an external AC/DC Power
Adapter (IEC Class II isolated only) with barrel
connector
NOTE 1: Local power supply used must have
its output isolated from Earth potential.
NOTE 2: If voltage of local power supply is
lower than the power voltage provided from
the PoE switch, then power on the PoE switch
should be turned off.
1W
-40°C to +70°C (-40°F to +158°F)
Tests conducted against international safety
standard at maximum ambient temperatures of
50ºC
20+ years
10% to 95% (non-condensing) at 35° C
Copyright 2019 NVT Phybridge
445-0024-A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EC4 and is the answer not in the manual?

Questions and answers

Summary of Contents for NVT Phybridge EC4

  • Page 1 • Local power option EC4 Adapter Applications The EC4 Adapter enables extended Ethernet and PoE reach beyond traditional distances using coax infrastructure. When paired with the CLEER24 Switch, EC10 Switch or EC-Base Extender, the Adapter delivers 100Mbps, symmetrical full duplex. The EC offering is designed specifically to enable easy deployment over coax for reaches beyond that of...
  • Page 2 4. Connect the Network Infrastructure cable from the CLEER24 switch, EC10 switch, or EC-Base to the EC4 (LRE side). 5. Using CAT5 or higher category cable, connect the endpoint to EC4 (Endpoint side). Endpoint device must be IEEE 802.3 af/at compliant.

This manual is also suitable for:

Nv-ec-04

Table of Contents