VALIDATE | After sensors are all placed
1. Log in to wpa.steelcase.com with a laptop or mobile device and navigate to the Device Manager tab.
2. Find the space you are validating.
3. Confirm all the sensors in the space are showing as "Online" (green) in the Workplace Advisor Device Manager (see below).
4. Confirm all sensors are detecting motion correctly by following the process below:
-
Have everyone leave the area for 2 minutes.
-
Verify all sensors change to "Unoccupied" in Workplace Advisor; if they don't, investigate what is causing them to detect motion.
-
Stand and/or sit at work area to ensure sensor is reading activity.
-
Repeat for each work area to trigger each sensor and watch each change to "Occupied" in Workplace Advisor.
-
Leave work area again, verify that all sensors change to "Unoccupied."
5. Sign off on each space on printed install plans to keep track of progress.
6. [Optional] Remove 2D code from the front of sensor once it has been fully validated as functional on Workplace Advisor.
7. Inform customer that sensor installation is complete once all spaces are validated.
Step 3
Step 2
Gateway Name (5)
online
offline
Step 4
occupied
unoccupied
NOTICE
The number shown for each sensor is its serial
number (found on the product label inside the
battery cover and package label or by scanning
the 2D code on the front housing).
2D code can be scanned using a phone
app to verify sensor's serial number
Page 7 of 26
1125807001 Rev B

Advertisement

loading

This manual is also suitable for:

Worksurface sensor kit