Download Print this page

Steelcase Workplace Advisor Installation Instructions Manual page 4

Advertisement

Available languages

Available languages

®
PLACE
Rules of Placement (fixed and adjustable-height tables)
1. Sensor lens should point towards the occupant where motion will be sensed and not blocked by any objects.
2. Sensor must be located correctly, according to position guidelines noted below:
a. The sensor should ideally be placed 16"-19" from the front edge of the worksurface, the sensor MUST be
placed a minimum of 6" from the edge of the worksurface, but 16"-19" is best for optimal operation.
b. The sensor lens should be centered within the occupant's primary work area.
c. If the sensor cannot be mounted 16"-19" from the front edge of the worksurface, be sure to adjust
sensor alignment tab as noted in the table below.
d. If there is a keyboard table, slide keyboard table all the way in. Place sensor on the underside of the
keyboard table 16"-19" from edge of worksurface or a minimum of 6" from edge of worksurface; be
sure to adjust sensor alignment tab as noted in the table below.
3. To support ideal gateway pairing, DO NOT activate sensors before they are in the space where they will be installed.
4. If possible, avoid installing on metal surfaces; mounting to metal surfaces can reduce connection range to gateway
and/or data loss.
5. The sensor alignment tab must be inserted into the correct slot in the mounting bracket and the mounting bracket
should be on the left or right depending on the slot position, as noted below:
Distance from front
edge of worksurface
Mounting bracket to the RIGHT
6"-12"
12"-19"
Position II
Position I
alignment tab
If in doubt about installation placement, contact Steelcase Customer Experience (CX).
Sensor mounting slot
Position I (20˚)
X
Sensor mounting slot
Position II (30˚)
Mounting bracket to the LEFT
X
Position I
Position II
Mounting bracket
Mounting bracket
to the RIGHT
to the LEFT
Sensor lens must
point toward occupant
6" min.
19" max.
centered
Sensor lens should be
centered with the
primary work area
Page 4 of 26
1125807001 Rev B

Advertisement

loading

This manual is also suitable for: