PLACE
1. Sensor must be located according to the position guidelines on the previous page.
2. Both adhesive strip and mechanical screw mounting methods must be used to mount sensor.
3. Make sure surfaces are clean prior to placing sensor. Use supplied alcohol wipe to clean surface.
Allow at least 15 seconds to dry. There should be no visible moisture after drying completely.
4. Remove the backing off on the adhesive strip that is pre-installed on the mounting bracket.
5. Apply bracket base to the surface and apply firm pressure for a least 15 seconds.
6. Insert the screw provided in mounting kit into one of the two holes on the mounting bracket (Figure 1)
and screw to bottom of worksurface. DO NOT overtighten as this can break the mounting bracket.
7. Insert mounting bracket base into the mounting bracket cover using the alignment pin, rotating the
base until it snaps into position (see Figure 2).
8. The sensor alignment tab must be inserted into the correct slot in the mounting bracket
following the position guidelines and table on the previous page (Figure 3).
Figure 1
screw holes
bracket cover
If in doubt about installation placement, contact Steelcase Customer Experience (CX).
mounting
bracket base
mounting
Figure 2
NOTICE
Once the sensor is inserted into the
bracket it will lock into place and cannot
be removed without disassembly.
If a sensor needs to be removed or
repositioned into a different mounting slot,
see removal directions on the next page.
Figure 3