olympia electronics BS-409 Quick Start Manual

Pir & microwave detector for conventional alarm panel

Advertisement

BS-409
OPERATION VOLTAGE
IDLE CONSUMPTION
ACTIVATION CONSUMPTION
DETECTION ANGLE
DETECTION RANGE
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
ACTIVATION PERIODE
ACTIVATED RELAY OUTPUT
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIAL
EXTERNAL DIMENSIONS
TYPICAL WEIGHT
GUARANTEE
Thank you for purchasing this product of Olympia Electronics. A European manufacturer.
The BS-409 has a Wide Angle lens, fourfold infrared sensor and microwaves, with new electronic
circuits that minimize the false alarms, and avoid the alarm conditions caused by small animals.
The detector also has a bi directional temperature compensation circuit, for unvarying detection for all
the periods of the year.
In the figures bellow are showed the main detector's parts.
Page 1 from 3
PIR & microwave detector
for conventional alarm panels

TECHNICAL CHARACTERISTICS

N.C 28VDC 0.1A with 10Ω series protection resistor (open when cover is removed)
Holding screw
LED
indicators
Lens
High Quality European based Manufacturers
8.2 - 16V DC
25.5mA DC
16.5mA DC
90
5-18m, adjustable
IP 40
EN 50130-4, EN 55022, EN 60950-1
2(+/- 1)sec
-20 to 50 C
Up to 95%
ABS
115x61x37.5mm
100 gr
2 years
Cable entrance
Mounting
knockout
Corner
mount
knockout
o
Bracket
921409000_09_003
holding
screw

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BS-409 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for olympia electronics BS-409

  • Page 1 Thank you for purchasing this product of Olympia Electronics. A European manufacturer. The BS-409 has a Wide Angle lens, fourfold infrared sensor and microwaves, with new electronic circuits that minimize the false alarms, and avoid the alarm conditions caused by small animals.
  • Page 2 Description of the detector adjustments Connection terminals ΜW sensitivity Microswitche’s operation control LED’s are enabled OFF ON -12V+ TAMP EOLRELAY LED’s are disabled OFF ON High sensitivity. 2 pulses for stable indication OFF ON environment. LED’s Low sensitivity. 3 pulses for TAMPER OFF ON harsh environment.
  • Page 3 Unscrew the holding screw and gently raise the front cover. Carefully unscrew the PCB holding screw located on the PC board. Break out the desired knockout holes for proper installation. The circular and rectangular indentations at the bottom base are the knockout holes for wire entry. You may also use mounting holes that are not in use for running the wiring into the detector.

Table of Contents