Pneumatic double diaphragm pump
Table of Contents

Advertisement

Introduce water into the pump tank.
Close the delivery valve (H1) and open the recirculation valve
(H2).
H1
Closed
Turn the pressure adjustment knob (H3) clockwise to start
the pump.
H3
MINIPEGASO
Insert the recirculation hose (H4) in the product collection
receptacle.
Open
H2
Slowly start the pump until all the liquid in the tank and the
pump has drained out.
Repeat this operation several times until complete clea-
ning.
Close the recirculation valve (H1) and open the delivery valve
(H2).
H1
Open
Place the recirculation hose back into the tank.
Slowly start the pump.
12
H4
Closed
H2