Introduce water into the pump tank.
•
Close the delivery valve (H1) and open the recirculation valve
(H2).
H1
Closed
•
Turn the pressure adjustment knob (H3) clockwise to start
the pump.
H3
MINIPEGASO
•
Insert the recirculation hose (H4) in the product collection
receptacle.
Open
H2
•
Slowly start the pump until all the liquid in the tank and the
pump has drained out.
Repeat this operation several times until complete clea-
ning.
•
Close the recirculation valve (H1) and open the delivery valve
(H2).
H1
Open
•
Place the recirculation hose back into the tank.
•
Slowly start the pump.
12
H4
Closed
H2