Fault
Rust spots on cutlery.
Detergent residue is present
in the detergent dispenser
or the tablet collecting tray.
Excessive formation of foam
occurs.

Information on display panel

Fault
Special salt refill indicator
lights up.
Refill indicator for special
salt does not light up.
Refill indicator for rinse aid
lights up.
Refill indicator for rinse aid
does not light up.
Display flashes.
Cause
Salt content in washing wa-
ter is too high.
Spray arms were blocked by
tableware so detergent was
not rinsed out.
Detergent dispenser was
damp when detergent was
added.
Hand washing-up liquid is
present in dispenser for
rinse aid.
Rinse aid has been spilled.
Detergent or appliance care
product used causes excess-
ive foaming.
Cause
Insufficient special salt.
Sensor does not detect spe-
cial salt tablets.
Water softening system is
switched off.
Insufficient rinse aid.
Rinse aid system is switched
off.
Appliance door is not closed
properly.
Troubleshooting en
Troubleshooting
Remove any spilled special salt
1.
from the tub.
Screw the cap of the special salt
2.
dispenser on tight.
Check that the spray arms are not
blocked and can rotate freely.
Only add detergent to a detergent
dispenser when dry.
Immediately add rinse aid to the
dispenser.
→ "Adding rinse aid", Page 31
Remove the rinse aid with a cloth.
Change the brand of detergent.
Troubleshooting
Add "Special salt" → Page 29.
Do not use special salt tablets.
"Setting water softening system"
→ Page 29
Add "Rinse aid" → Page 31.
1.
Set the amount of rinse aid to be
2.
dispensed.
→ "Setting the amount of rinse aid",
Page 31
Close the appliance door.
Arrange the tableware so
that no parts project beyond
the basket and prevent the
appliance door from closing
properly.