Garage Door Systems ThermaRoll 77 Installation Instructions Manual page 31

Roller garage door
Table of Contents

Advertisement

DESCRIPTION OF FAULT
Door will only close in
dead man mode
Alarm is not
sounding
The control unit is not
responding
The control unit is
completely dead
and no response is
registering with the
control.
The door is closing on
its own
The door only
operates on the Key
Fob and will not
respond on the control
panel
TROUBLESHOOTING GUIDE
DIAGNOSIS
Control panel number 2
light will be illuminated
indicating that no light
is detected through the
rubber.
When the door is at the
bottom limit and the rubber
is compressed the alarm
should sound for 2 minutes
unless cancelled with one
press of a key fob button.
Although the unit is not
responding, can you hear
the control unit click when
trying to execute an up or
down command? On the
control unit does the red
motor light (1st light) flash?
If trying to send a command
from a key fob do you hear
a click and the motor light
and Prog light flash?
The fuse within the plug has
possibly blown and needs to
be replaced.
Remove the front cover on
the control unit and check
if the red light beside the T
button is on. This indicates
that the auto close function
is on.
When holiday mode
is active, each time a
programmed control
(control panel interface or
remote control) is pressed,
indicator lights 1,2,3 and
the Prog start flashing for 2
seconds.
POSSIBLE CAUSE
Is the bottom rubber
crushed? Are any of the
guides set into a hole? Is the
threshold uneven?
The control unit has not
been issued with the Alarm
factory set
Fuse blown - normal fuse
failure relating to the motor
or light bulb.
Fuse blown - normal fuse
failure.
Auto close has been
activated.
Holiday mode has been
activated.
SOLUTION
Resolve the issue that is
preventing the bottom
rubber from transmitting the
light beam.
The alarm should be pre-
set to "on" as standard. To
disarm, press and hold the
down (v) button and (STOP)
button simultaneously, untill
all lights on the control
unit flash and then release
the buttons. The alram is
now deactivated. Carry
out the same procedure to
reactivate.
Replace the fuse in the
black fuse holder with spare
housed below.
Replace the fuse in the
plug. If issue is not resolved
contact GDS to advise
possible faulty unit.
Press the T button to
deactivate the Auto Close
function. The red light will
go out to signify this has
been cancelled.
To activate / deactivate
holiday mode press the
"STOP" button until the 4
indicator lights flash rapidly
for 2 seconds.
31

Advertisement

Table of Contents
loading

Related Products for Garage Door Systems ThermaRoll 77