Indoor Installation; Camera Dome; Mounting; Base - American Dynamics SpeedDome Ultra 8 Installation And Service Manual

Camera dome
Hide thumbs Also See for SpeedDome Ultra 8:
Table of Contents

Advertisement

Indoor Installation

This section explains how to connect the housing
and eyeball assembly to a mounting base.
Items You Will Need
You should have on hand the following tools and
parts:
• Install/Removal tool to attach and detach domes
and bubbles without a ladder.
• Base kit: ADSDUIOB (black) or ADSDUIOBW
(white).
• SpeedDome Ultra 8 housing and eyeball
assembly, 0101-0150-xx.
Other Preparations
To ensure a smooth and successful installation,
you must:
• Have electrical work comply with latest national
electrical code, national fire code, and all
applicable local codes and ordinances.
• Coordinate work with other trades to avoid
interference.
• Verify existing site conditions and coordinate
with the owner's representative and appropriate
utilities as required.
• Obtain copies of all related plans, specifications,
shop drawings and addenda to schedule and
coordinate related work.
• Thoroughly review the project to ensure that all
work meets or exceeds the above requirements.
Bring alleged discrepancies to the attention of
the CCTV Project Coordinator.

SPEEDDOME ULTRA 8 CAMERA DOME

INSTALLATION AND SERVICE GUIDE
Connecting to the Mounting Base
WARNING:
!
electrical signals are off during wire
connections!
Referring to Figure 9:
1. Set termination jumper JW1 according to the
dome's position in the communications line.
Position of dome in
communications line...
Between other devices
End of communications line
Note: You may need a small slotted screwdriver
to gently pry jumper loose. Be careful not to
damage the PC board.
2. Connect the video cable to I/O board BNC video
cable extension.
3. Connect Manchester, RS-422, or SensorNet
485 data wires to connector TB1. If using a
Pelco Coaxitron or Panasonic UTC protocol, no
data wires are connected, just power.
Manchester data connections.
Order data cable 88760 (plenum) or 8760 (non-
plenum) from Belden by calling 1-800-235-3361.
Pin
Color
1-4
5
Black
6
White
RS-422 data connections
Pin
Color
1
Orange
2
Green
3
Yellow
4
Brown
5-6
SensorNet data connections
Pin
Color
1-4
5
Orange
6
Yellow
10 of 30
Ensure that ac power and
Setting
Unterminated
Terminated
Designation
Not used.
Manchester (+)
Manchester (–)
Designation
RS-422 Data In High (+)
RS-422 Data In Low (–)
RS-422 Data Out High (+)
RS-422 Data Out Low (–)
Not used.
Designation
Not used.
SensorNet (unshielded)
SensorNet (unshielded)
8200-0600-03, REV. B
Pins
Off
1-2

Advertisement

Table of Contents
loading