Kingfisher KI7400 Series Training Manual
Hide thumbs Also See for KI7400 Series:

Advertisement

Quick Links

1
Training Manual:
Training Manual:
KI7400 & 7800 Series Sources
KI7400 & 7800 Series Sources
Level 1, V2.0
Level 1, V2.0
August 2008

Advertisement

loading
Need help?

Need help?

Do you have a question about the KI7400 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Kingfisher KI7400 Series

  • Page 1 August 2008 Training Manual: Training Manual: KI7400 & 7800 Series Sources KI7400 & 7800 Series Sources Level 1, V2.0 Level 1, V2.0...
  • Page 2 Course Contents Course Contents Course Contents Course Contents General features General features Instrument setup Instrument setup Models Sending light & test tone Instrument care Change test tone frequency...
  • Page 3: General Features

    1 / G 1 / G 1./ General Features 1./ General Features Autotest capability Autotest capability Very long battery life Very long battery life – 190 hours 190 hours Autotest compatible with Agilent N DC power socket series instruments Optical test tone generator Single port for MM Single port for SM Single port for MM, Single port for SM I d t...
  • Page 4 2 / M d l 2 / M d l 2./ Models 2./ Models There are two model styles: 1. KI7400 Series - preferred by telcos & those requiring higher stability Ultra Stable laser light source Single port Up to 4 laser λs Zero warm up 2.
  • Page 5 3 / I 3 / I 3./ Instrument care 3./ Instrument care Keep the instrument in its carry case during storage and transport Use only high quality batteries. For prolonged storage remove batteries. The instrument is resistant to normal dust and moisture, however it is not waterproof. If moisture gets into the instrument, remove batteries &...
  • Page 6 4./ Prepare Instrument 4./ Prepare Instrument a) Keypad b) Fit batteries b) Fit batteries c) Power On / Off d) Launch / Test cord configuration d) Launch / Test cord configuration e) Fit / remove adaptors...
  • Page 7 a./ Keypad a./ Keypad Hidden keypad Connector Connector Power On / Off Power On / Off RS232 Model: Backlight USB Model: No function Four soft buttons ft b tt λ toggle Battery Battery Compartment...
  • Page 8 b / Fit batteries b / Fit batteries b./ Fit batteries b./ Fit batteries To Fit Batteries. Hold instrument in 2 hands with thumbs resting on battery compartment latch Hold instrument in 2 hands with thumbs resting on battery compartment latch. Press latch down and push away from case.
  • Page 9 c./ Power On / Off c./ Power On / Off O / Off O / Off 10 minutes auto Off or Permanent operation Low battery Push the oval indicator [POWER] button to turn ON or OFF To defeat auto time out. To defeat auto time out.
  • Page 10 d / L d / L d./ Launch / Test cord configuration d./ Launch / Test cord configuration h / T h / T The light source is either PC or APC connector specific. This is determined when ordering the instrument and can only be changed at the factory when ordering the instrument, and can only be changed at the factory.
  • Page 11 e./ Adaptor e./ Adaptor - - fitting / Ad / Ad fitti fitti fitting...
  • Page 12: Current Models

    Adaptor Adaptor - - removal removal Current models: Locate quick release button on rear of instrument at base of connector housing Push and hold button in Pull out existing adaptor Fit new adaptor Fit new adaptor Remove as per ‘early models’ Early models: Move adaptor interface to mid position Pull out existing adaptor...
  • Page 13 5./ Sending Light 5./ Sending Light Source can be operated in one of 3 ways: a) Autotest: automatically toggle between all λs automatically toggle between all λs Preferred mode for loss testing as testing time is greatly reduced. Minimises error as meter always displays correct λ. b) Manual: Single λ...
  • Page 14: Start Autotest

    a./ Auto Test Mode a./ Auto Test Mode Start Autotest: [Auto test] Press [Auto test] LCD displays: <<< &/Or >>> indicating LCD displays: <<< &/Or >>> indicating the active port 1550 Source on Transmitted data: nominal output power, <<< serial number & λ serial number &...
  • Page 15 b./ Manual Mode b./ Manual Mode Source On: [Source] Press [Source] Source off Source displays, λ, nominal output power & active port: <<< / >>> Auto test Source Source Toggle [-/+] to select λ or turn off 1550 [-/+] Source 0 00 0.00 <<<...
  • Page 16 c./ Test Tone c./ Test Tone Instrument must be in Manual Mode not Autotest Modulation On: Press [Source] [Source] Press [Mod] Modulation wavelength is displayed e.g. 2000Hz 1550 1550 Perm 2000 Source on 0.00 <<< Menu [Mod] Modulation Off: Press [Mod] or Press [Menu]...
  • Page 17 6 / Ch 6 / Ch 6./ Change modulation frequency 6./ Change modulation frequency d l ti d l ti RS232 Models SOURCE METER SHIFT LEVEL dBm/w MAX/MIN Set up source in manual mode CANCEL SET SELECT RECALL STORE Open Hidden keypad MEMORY Press [KHz]...
  • Page 18 USB Models Default KHZ Level Max/Min dB/W dB/W RL-NF RL-Adj RL NF RL Adj Set up source in manual mode Open Hidden keypad Open Hidden keypad Exit Press [Г] then [KHz] 2000 2000 Source Toggle [-/+] to scroll : 270Hz, 1kHz, 2kHz Press [Set] to select tone frequency...
  • Page 19: Application Notes

    Application Notes Application Notes Comprehensive selection available at www.kingfisher.com.au/ApplicationNotes.htm fi h li ti...