Download Print this page

Endress+Hauser Levelflex FMP50 Safety Instructions page 22

Electrical apparatus for explosion hazardous areas
Hide thumbs Also See for Levelflex FMP50:

Advertisement

XA00499F-F
22
U
[V]
max
35
34
33
32
31
30
29
28
27
For values associated with a higher or lower internal power consumption please contact
Endress+Hauser.
Terminal 1 (+), 2 (–)
Power supply:
U
= 35 V
N
DC
U
= 250 V
m
I
= 22 mA
max
Basic specification, Position 3 (Power Supply, Output) = C
Terminal 1 (+), 2 (–)
Power supply:
U
= 30 V
N
DC
U
= 250 V
m
I
= 22 mA
max
Basic specification, Position 3 (Power Supply, Output) = K
Terminal 1 (+), 2 (–)
Power supply:
U
= 253 V
; 50/60 Hz
N
AC
U
= 250 V
m
I
= 25 mA
N
I
= 160 mA
max
Basic specification, Position 3 (Power Supply, Output) = L
Terminal 1 (+), 2 (–)
Power supply:
U
= 48 V
N
DC
U
= 250 V
m
I
= 112 mA
N
I
= 300 mA
max
Levelflex FMP50/51/52/53/54/55
R
min
V
205 Ω
177 Ω
150 Ω
122 Ω
95 Ω
67 Ω
39 Ω
12 Ω
0 Ω
Terminal 3 (+), 4 (–)
Switch output (PFS):
U
= 35 V
N
DC
U
= 250 V
m
Terminal 3 (+), 4 (–)
Output 4 to 20 mA:
U
= 30 V
N
DC
U
= 250 V
m
I
= 22 mA
max
Terminal 3 (+), 4 (–)
Output 4 to 20 mA:
U
= 22 V
N
DC
U
= 250 V
m
I
= 22 mA
max
Terminal 3 (+), 4 (–)
Output 4 to 20 mA:
U
= 22 V
N
DC
U
= 250 V
m
I
= 22 mA
max