Walinga Central Vac Installation Manual page 8

Hide thumbs Also See for Central Vac:

Advertisement

2. Airlock / Rotary Valve
The airlock is a Walinga 1210 drop thru airlock, built as a single assembly.
27 1/2" long X 23" wide.
The airlock will be placed under the primary separator and above the customer's
discharge option, which will be indicated on the piping layout / system design
drawings.
Discharge piping is 6" and
should be installed vertically with
a maximum of 20deg slope. This
ensures that dust will flow
through spouting using only
gravity.
The airlock operates off of an
electric motor and chain drive
and has to be placed in an easily
accessible location for service.
3. Secondary Receiver / Separator
Placed after the primary separator, the secondary separator operates the same
way as the primary. It's purpose is to further separate product from the air
stream.
It typically ships as two pieces that need to be assembled.
On the bottom of the secondary separator is a 6" outlet with a mounting plate
built into it. Below this will be a slide gate or a flap seal.
When equipped with a slide gate 6" discharge spouting will be required.
When equipped with a flap seal ensure there is enough room below to empty
the cone into an appropriate container
70" high X 19" diameter.