Pressure relief 3-port valve with locking holes (13 pages)
Summary of Contents for SMC Networks VXF2 Series
Page 1
2 Port Solenoid Valve/Air Operated Valve ∗ For Dust Collector RoHS Large port Piping Power sizes available. Faston terminal Enclosure consumption type added Port size Flange type, ∗ IP65 50A to 100A Flange body type ∗ Electrical entry ∗ ∗ Excluding size 23 “Faston”...
Page 2
2 Port Solenoid Valve/Air Operated Valve For Dust Collector Enclosure Enclosure Power consumption Power consumption IP65 IP65 (Size 21, 22, 24, 25, 26, 27, 28) (Size 23) Low-noise Low-noise Improved armature Improved armature construction construction durability durability Impact noise reduced by the rubber buffer Flame resistant Flame resistant...
Page 3
Dedicated Controller For VXF(A)2/Series VXFC Page 30 The valve controller turns ON/OFF multiple valves for the dust controller. Power supply voltage 24 VDC to 48 VDC Application example 2 port solenoid valve for dust collector (VXF2) 6 outputs, Number of outputs Blow tube Nozzle 10 outputs...
Page 4
VXF2 Solenoid Valve Type Series Common Specifications/Selection Steps Specifications Solenoid Valve Type VXF21A VXF22A VXF23A VXF24A VXF25 VXF26 VXF27B VXF28B Part no. Orifice size [mmø] 1 1/2 2 1/2 3 1/2 Port size Fluid Minimum operating pressure [MPa] 0.03 Maximum operating pressure [MPa] Fluid temperature [°C] −10 (No freezing) to 60...
Page 5
VXF2 Series 2 Port Air Operated Valve For Dust Collector RoHS How to Order VXF2 1 Solenoid Valve Type Port thread (Only for direct piping type) Symbol Port thread Port size Piping Material – With/without silencer — Port Diaphragm/ With/without Symbol Symbol Piping...
Page 6
VXFA2 Air Operated Type Series Common Specifications/Selection Steps Specifications Air Operated Type VXFA21AA VXFA22AA VXFA23AA VXFA24A VXFA25(A,B) VXFA26(A,B,C,D) VXFA27B VXFA28B Part no. Orifice size [mmø] Port size 1 1/2 2 1/2 3 1/2 Fluid Minimum operating pressure [MPa] 0.03 Maximum operating pressure [MPa] Fluid temperature [°C] −10 (No freezing) to 60...
Page 7
VXF2 Series 2 Port Air Operated Valve For Dust Collector RoHS How to Order Common Specifications VXFA2 1 Air Operated Type Diaphragm/Main valve material NBR/POM Port thread (Only for direct piping type) Port size Piping Symbol Port thread — Port Symbol Symbol Piping...
Page 8
VXF2/VXFA2 Series Valve Characteristics The valve characteristics data was measured with the stated outlet piping length. The valve characteristics vary depending on the tank capacity, air supply, set pressure, outlet conditions (nozzle size, quantity, piping length), so please use these values as a guideline.
Page 9
VXF2/VXFA2 Series Valve Characteristics 1. Response Time, Start-up Speed VXF2/For solenoid valve type, the piping length to the pilot valve should be 0 mm. ON Response Time Start-up Speed 0.05 0.04 VXFA23A 0.03 0.02 VXFA21A VXFA22A VXFA22A VXFA21A 0.01 1000 1500 1000 1500...
Page 10
VXF2/VXFA2 Series 2. Discharge Volume VXF2/For solenoid valve type, the piping length to the pilot valve should be 0 mm. VXF2 Type VXFA2 Type Measuring conditions Measuring conditions Test circuit …Refer to the circuit below. …Refer to the circuit below. Test circuit Test sample …...
Page 11
2 Port Solenoid Valve/Air Operated Valve VXF2/VXFA2 Series For Dust Collector Construction Solenoid Valve Type Air Operated Type VXF2 A VXFA2 A /Direct piping type /Direct piping type VXF2 A VXFA2 A /Direct piping type /Direct piping type Component Parts Component Parts Description Material...
Page 12
VXF2/VXFA2 Series Construction Solenoid Valve Type Air Operated Type VXF2 B VXFA2 B /Flange type /Flange type VXF26C VXFA26C /Flange body I type /Flange body I type VXF26D VXFA26D /Flange body II type /Flange body II type Component Parts Component Parts Description Material Description...
Page 13
VXF2 Series 2 Port Air Operated Valve For Dust Collector Direct piping type VXF21A /22A /23A Dimensions: Grommet Grommet (with surge voltage suppressor) ≈ 300 ≈ 300 Exhaust port Exhaust port Port size Port size DIN terminal Cable ø6 to ø12 G1/2 Exhaust port Port size...
Page 14
VXF2 Series Direct piping type VXF21A /22A /23A Dimensions: Conduit terminal Conduit ±2 ±2 ≈ 280 G1/2 G1/2 Exhaust port Exhaust port Port size Port size Faston terminal Exhaust port Port size Dimensions [mm] Port size Model VXF21A 53.5 29.5 68.5 16.5 VXF22A...
Page 15
VXF2 Series 2 Port Air Operated Valve For Dust Collector Direct piping type VXF24A Dimensions: Grommet Grommet (with surge voltage suppressor) ≈ 300 ≈ 300 12.5 Exhaust port 12.5 Exhaust port Port size DIN terminal Cable ø6 to ø12 12.5 Exhaust port G1/2 Port size...
Page 16
VXF2 Series Direct piping type VXF24A Dimensions: Conduit terminal Conduit ±2 ±2 ≈ 280 12.5 Exhaust port 12.5 Exhaust port G1/2 G1/2 2 × 2 × Port size Port size Faston terminal 12.5 Exhaust port 2 × Port size Dimensions [mm] Port size Model...
Page 17
VXF2 Series 2 Port Air Operated Valve For Dust Collector Direct piping type VXF25A /26A Dimensions: Grommet Grommet (with surge voltage suppressor) ≈ 300 ≈ 300 Exhaust port Exhaust port 24.4 24.4 2 × 2 × Port size Port size DIN terminal Cable ø6 to ø12 24.4...
Page 18
VXF2 Series Direct piping type VXF25A /26A Dimensions: Conduit terminal Conduit Q±2 ±2 ≈ 280 24.4 Exhaust port 24.4 Exhaust port G1/2 G1/2 Port size Port size Faston terminal 24.4 Exhaust port Port size Dimensions [mm] Port size Model VXF25A 2 1/2 117.5 18.6...
Page 19
VXF2 Series 2 Port Air Operated Valve For Dust Collector Flange type VXF25B /26B /27B /28B Dimensions: Grommet Grommet (with surge voltage suppressor) ≈ 300 ≈ 300 24.4 24.4 Exhaust port Exhaust port ø ø DIN terminal Cable ø6 to ø12 24.4 Exhaust port G1/2...
VXF2 Series Flange type VXF25B /26B /27B /28B Dimensions: Conduit terminal Conduit ±2 ±2 ≈ 280 24.4 24.4 Exhaust port Exhaust port G1/2 G1/2 ø ø Faston terminal 24.4 Exhaust port ø Note) Refer to page 18 for the dimensions of the mounting interface. Dimensions [mm] Model...
Page 21
VXF2 Series 2 Port Air Operated Valve For Dust Collector Flange type Dimensions of the Mounting Interface: VXF25B VXF26B 8 x M10 x 1.5 x 20 8 x M8 x 1.25 x 20 The surface roughness of the orifice should be Rz6.3 or less. The surface roughness of the orifice should be Rz6.3 or less.
Page 22
VXF2 Series Flange body I type VXF26C Dimensions: Grommet Grommet (with surge voltage suppressor) ≈ 300 ≈ 300 24.4 24.4 Exhaust port Exhaust port 6 x M10 x 1.5 x 30 6 x M10 x 1.5 x 30 ø106 ø106 DIN terminal Cable ø6 to ø12 24.4...
Page 23
VXF2 Series 2 Port Air Operated Valve For Dust Collector Flange body I type VXF26C Dimensions: Conduit terminal Conduit ±2 ≈ 280 ±2 24.4 Exhaust port 24.4 Exhaust port G1/2 G1/2 6 x M10 x 1.5 x 30 6 x M10 x 1.5 x 30 ø106 ø106 Faston terminal...
Page 24
VXF2 Series Flange body II type VXF26D Dimensions: Grommet Grommet (with surge voltage suppressor) ≈ 300 ≈ 300 24.4 24.4 Exhaust port 8 x M10 x 1.5 x 75 8 x M10 x 1.5 x 75 ø106 ø106 DIN terminal Cableø6 to ø12 24.4 Exhaust port...
Page 25
VXF2 Series 2 Port Air Operated Valve For Dust Collector Flange body II type VXF26D Dimensions: Conduit terminal Conduit ±2 ±2 ≈ 280 24.4 Exhaust port 24.4 Exhaust port 8 x M10 x 1.5 x 75 8 x M10 x 1.5 x 75 G1/2 G1/2 ø106...
Page 26
VXF2 Series Flange body I/II type Dimensions of the Mounting Interface: VXF26C VXF26D 6 x M10 x 1.5 x 20 8 x M10 x 1.5 x 20 VXF26C VXF26D Piping Piping ±0.8 ±0.8 ø89.1 ø89.1 ø80 or more ø80 or more 80A Steel tube 80A Steel tube Piping...
Page 27
VXF2 Series 2 Port Air Operated Valve For Dust Collector Direct piping type Dimensions: VXFA21A VXFA22A VXFA23A Pilot port Port size Dimensions [mm] Port size Model VXFA21A 64.5 53.5 29.5 VXFA22A 74.5 23.5 64.5 29.5 VXFA23A 1 1/2 VXFA24A Pilot port Exhaust port Port size Dimensions...
Page 28
VXFA2 Series Direct piping type Dimensions: VXFA25A VXFA26A Pilot port Exhaust port Port size Dimensions [mm] Port size Model 2 1/2 117.5 102.8 59.8 VXFA25A VXFA26A 102.8 59.8...
Page 29
VXFA2 Series 2 Port Air Operated Valve For Dust Collector Flange type Dimensions: VXFA25B VXFA26B VXFA27B Pilot port VXFA28B Exhaust port ø Note) Refer to page 27 for the dimensions of the mounting interface. Dimensions [mm] Model — — VXFA25B 18.3 102.8 59.8...
Page 30
VXFA2 Series Flange type Dimensions of the Mounting Interface: VXFA25B VXFA26B 8 x M10 x 1.5 x 20 8 x M8 x 1.25 x 20 The surface roughness of the orifice should be Rz6.3 or less. The surface roughness of the orifice should be Rz6.3 or less. ±0.3 ø156 ±0.3...
Page 31
VXFA2 Series 2 Port Air Operated Valve For Dust Collector Flange body I/II type Dimensions: VXFA26C VXFA26D (102.8) (102.8) (59.8) (59.8) Pilot port Exhaust port Pilot port Exhaust port 8 x M10 x 1.5 x 75 6 x M10 x 1.5 x 30 ø106 ø106 Note) Refer to page 29 for the dimensions of the mounting interface.
Page 32
VXFA2 Series Flange body I/II type Dimensions of the Mounting Interface: VXFA26C VXFA26D 6 x M10 x 1.5 x 20 8 x M10 x 1.5 x 20 VXFA26C VXFA26D Piping Piping ±0.8 ø89.1 ±0.8 ø89.1 ø80 or more ø80 or more 80A Steel tube 80A Steel tube Piping...
Page 33
2 Port Solenoid Valve/Air Operated Valve VXF2/VXFA2 Series For Dust Collector RoHS Dedicated Controller For VXF(A)2/Series VXFC How to Order Controller VXFC 06 Voltage Number of output points 6 outputs 24 to 48 VDC 10 outputs Specifications Model VXFC D Input voltage 24 to 48 VDC Output voltage...
VXF2/VXFA2 Series Specific Product Precautions 1 Be sure to read before handling. Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) and the Operation Manual for 2 Port Solenoid Valves for Fluid Control. Please download it via our website, http://www.smcworld.com 2 Port Solenoid Valve For Dust Collector Series VXF2/VXFA2 Design...
Page 35
VXF2/VXFA2 Series Specific Product Precautions 2 Be sure to read before handling. Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) and the Operation Manual for 2 Port Solenoid Valves for Fluid control. Please download it via our website, http://www.smcworld.com 2 Port Solenoid Valve For Dust Collector Series VXF2/VXFA2 Mounting...
Page 36
VXF2/VXFA2 Series Specific Product Precautions 3 Be sure to read before handling. Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) and the Operation Manual for 2 Port Solenoid Valves for Fluid Control. Please download it via our website, http://www.smcworld.com 2 Port Solenoid Valve For Dust Collector Series VXF2/VXFA2 Operating Environment...
Page 37
VXF2/VXFA2 Series Specific Product Precautions 4 Be sure to read before handling. Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) and the Operation Manual for 2 Port Solenoid Valves for Fluid Control. Please download it via our website, http://www.smcworld.com 2 Port Solenoid Valve For Dust Collector Series VXF2/VXFA2 Electrical Connections...
Page 38
VXF2/VXFA2 Series Specific Product Precautions 5 Be sure to read before handling. Refer to back cover for Safety Instructions, “Handling Precautions for SMC Products” (M-E03-3) and the Operation Manual for 2 Port Solenoid Valves for Fluid Control. Please download it via our website, http://www.smcworld.com Dedicated Controller For VXF(A)2 Series VXFC Wiring...
These safety instructions are intended to prevent hazardous situations and/or Safety Instructions equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for ∗1) safety and must be followed in addition to International Standards (ISO/IEC) and other safety regulations.
Need help?
Do you have a question about the VXF2 Series and is the answer not in the manual?
Questions and answers