PRODUCT NAME
V100 Series
MODEL/ Series

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the V100A and is the answer not in the manual?

Questions and answers

Summary of Contents for SMC Networks V100A

  • Page 1 Doc. No.V100-OMV0001-A 3 Port Solenoid Valve PRODUCT NAME V100 Series MODEL/ Series...
  • Page 2: Table Of Contents

    Contents Safety Instructions ---------------------------------------------------------------------------- 2,3 Design / Selection ---------------------------------------------------------------------------- 4,5 Mounting ---------------------------------------------------------------------------------------- 5 Piping -------------------------------------------------------------------------------------------- 6 Wiring -------------------------------------------------------------------------------------------- 6 Lubrication -------------------------------------------------------------------------------------- 7 Air Supply --------------------------------------------------------------------------------------- 7 Operating Environment ---------------------------------------------------------------------- 7 Maintenance ------------------------------------------------------------------------------------ 8 UL approved product -------------------------------------------------------------------------- 8 Specific Product Precautions --------------------------------------------------------------- 9,10 Trouble shooting ------------------------------------------------------------------------------- 11,12 No.V100-OMV0001-A...
  • Page 3: Safety Instructions

    Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) , and other safety regulations.
  • Page 4 Safety Instructions Caution 1. The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
  • Page 5: Design / Selection

    V100 Series Precautions for 3 Port Solenoid Valve 1 Be sure to read before handling. Design / Selection Confirm the specifications Leakage voltage Products represented in this instruction manual are designed Take note that the leakage voltage will increase when a only for use in compressed air systems ( including vacuum).
  • Page 6: Mounting

    V100 Series Precautions for 3 Port Solenoid Valve 2 Be sure to read before handling. Design / Selection 5. Operation in low temperature conditions It is possible to operate a valve in extreme temperatures, as 4. Surge voltage intrusion low as –10°C. Take appropriate measures to avoid the With non-polar type solenoid valves, at times of sudden freezing of drainage, moisture, etc., in low temperatures.
  • Page 7: Piping

    V100 Series Precautions for 3 Port Solenoid Valve 3 Be sure to read before handling. Piping For reuse Normally, fittings with a sealant can be reused up to 2 to 3 times. 1. Refer to the Fittings and Tubing Precautions for To prevent air leakage through the sealant, handling One-touch fittings.
  • Page 8: Lubrication

    V100 Series Precautions for 3 Port Solenoid Valve 4 Be sure to read before handling. Lubrication 4. If an excessive amount of carbon powder is present, install a mist separator on the upstream side of the valve. If excessive carbon dust is generated by the compressor, it 1.
  • Page 9: Maintenance

    V100 Series Precautions for 3 Port Solenoid Valve 5 Be sure to read before handling. Maintenance 1. Perform maintenance and inspection according to the procedures indicated in the operation manual. If handled improperly, human injury and/or malfunction or damage of machinery and equipment may occur. 2.
  • Page 10: Specific Product Precautions 1

    V100 series Specific Product Precautions 1 Be sure to read this before handling the products. Manual Override Operation 3. Attaching and detaching lead wires with sockets Since connected equipment will be actuated when the ・ Attaching manual override is operated, first confirm that conditions Insert the sockets into the square holes of the are safe.
  • Page 11 V100 series Specific Product Precautions 2 Be sure to read this before handling the products. Surge Voltage Suppressor Connector Assembly with Cover Connector assembly with protective cover enhances dust protection ・ Effective in preventing possible short circuit problems due to contaminants in contact with connector section.
  • Page 12: Trouble Shooting

    TROUBLE SHOOTING Should any trouble be found during operation, trace the source of the trouble in the following order and take corrective action. Trouble phenomenon Cause expected Measures ① Faulty operation Pilot valve is not operated Faulty wiring ② Blown fuse or disconnection lead wire ③...
  • Page 13 Remedy Remedy ① Re-wire correctly. ② Replace part. ③ Replace part or re-wire positively. ④ Replace pilot valve ass'y ・If wrong oil is used, completely air blow to remove oil, and replace valve.After valve is replaced, use turbin oil class 1 (ISO VG32). ⑤...
  • Page 14 Revision history A Specific Product Precautions 1 Revised CR 1st Printing :WQ 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. ©...