Installation and operating manual
3.3. Installation
The diagrams below show examples of BEKOMAT
NOTE
Installation instructions
•
•
•
•
•
•
•
BEKOMAT
3 CO Ex / 3 E Ex - condensate discharge rate < 360 l/h
®
*Mindesteinbauhöhe (mit Bodenhalter)
16
Install a separate BEKOMAT
Do not use cone-shaped fittings.
Keep the pipes as short as possible.
Do not install filters/dirt trap in the condensate inlet.
Only install ball valves in the condensate inlet line.
The venting line must be installed above the highest possible condensate level.
Observe the minimum installation heights.
1
2
3/6 installations for various condensation discharge rates.
®
at each point where condensate might be produced.
®
Upper condensate inlet (Ø ≥ ¾")
1
Permanently installed pipe at a continuous
gradient (≥ 1°).
Manual drain (Ø ≥ ¼") (recommended)
2
Permanently installed pipe at a continuous
gradient (≥ 1°)
Condensate discharge of solenoid valve
3
3
(Ø ≥ ½") Permanently installed pipe at a
continuous gradient (≥ 1°)
4
Condensate discharge of manual drain
4
(Ø ≥ ¼")
Permanently installed pipe at a continuous
gradient (≥ 1°)
We recommend installing a floor bracket.
BEKOMAT
3/6 CO Ex, 3/6 E Ex
®