Dimensions; Limit Switches; Duty Cycles; Life Line - Proteco MATRIX Installation And User Manual

Rack-driven sliding gate system
Table of Contents

Advertisement

2.3
Content
1
5
DESCRIZIONE
1
Gearmotor
2
Release key
3
Ground plate
4
Wires membrane
5
Anchor screws Grower M10
5
Washer Ø 10
5
4,2x13 self-threading screws
6
Anchor screws i M10
6
Bolt M10 + Washer M10
6
Washer M10
7
Limit switch cam LH
7
Limit switch cam RH
7
Dowel M6x10
2.4

Dimensions

361 mm
2.5

Limit switches

Picture 1: Mechanical limit switch
4
2
4
3
6
CODICE
QUANTITÀ
1
FLC2722
2
MPIS06
1
MPC06
1
MRO10EZ
4
8
MVI4213DI
2
MTRF10185Z
8
MDAM10Z
4
MRO10Z
8
MSLF01S
1
MSLF01D
1
MGR0610Z
4
227 mm
Picture 2: Magnetic limit switch
2.6

Duty cycles

The calculation of cycles refers to a gate of standard length, installed
according to the standards in force, free from mechanical and/or
accidental friction, with an outside temperature of 20 ° C, as per EN
60335-2-103 regulations.
The number of working cycles depends very much on the length
and weight of the gate, as well as the Matrix model choosen for the
installation.
Table 1: Gate Length
Matrix 2500 Matrix 1800 Matrix BLDC Matrix High
7
Gate length (m)
Max. Cycles/
Hour
Up to 6
28
From 6 to 10
14
From 10 to 12
12
From 12 to15
8
From 15 to18
-
Table 2: Reduction of duty cycle rate according to gate weight
Gate weight
600 Kg
From 600 to 1000
From 1000 to 1500
From 1500 to 1800
From 1800 to 2500
Example:
Gate length 10 m, gate weight 1500Kg, Matrix 2500
14 x 0,7 (70%) = 9,8
Approximately 10 cycles per hour
In addition, there may be other factors that can affect the shelf life
of the product.
Factors may vary depending on the environment in which the automation
is installed.
2.7

Life line

The life of the gearmotor may be affected by multiple waste factors.
The life expectation can be calculated using the criteria outlined in
the below table.
In order to get the waste rate add together all values that comply
with the installation scenario and according accessories.
ATTENTION:
If the waste rate obtained is beyond 10, move to a superior
version in order to fulfill the expected performances.
Normal operation frequently cut
due to obstacle
Seaside areas
Sandy and/or dusty areas
Outside temperatures often beyond
40° or below 0°
Max. Cycles/
Max. Cycles/
Hour
Hour
28
40
14
28
12
22
-
15
-
10
Matrix 2500/
Matrix 1800
Matrix BLDC
Duty cycle rate
Duty cycle rate
100
100
80
70
70
50
50
30
40
-
Matrix
Matrix
Matrix
2500
1800
BLDC
1
1
1
1
1
1
0,5
0,5
0,5
0,5
0,5
0,5
MATRIX - rev. 1.1_09_2020
Speed
Max. Cycles/
Hour
58
40
32
20
-
Matrix High
Speed
Duty cycle rate
100
70
50
30
-
Matrix
High
Speed
1,5
1
0,5
0,5

Hide quick links:

Advertisement

Table of Contents
loading