Electric Layout; Wires Features; Basement Preparation - Proteco MATRIX Installation And User Manual

Rack-driven sliding gate system
Table of Contents

Advertisement

3.3

Electric layout

Picture 3: Electric layout
Refer to next chapter.
3.4

Wires features

Cables necessary for the installation of the system (not
included) may vary according to the quantity and type of
accessories and devices fitted.
A
Safety edge
B
Power supply
C
Photocells
Photocells
D
Key switch
E
Blinker
3.5

Basement preparation

It is absolutely key to build a solid concrete basement (at least
EN206 C25/30 proof).
Basement dimensions must be no less than 500x300mm and no
less than 400mm deep.
We recommend to consider an extra concrete surface of 100 mm
all around the basement. (Picture 4).
Picture 4: ferro concrete basement
6
D
230V
24V
2x0,5
2x0,5
2x1,5+T
2x1,5+T
Rx 4x0,5
Rx 4x0,5
Tx 2x0,5
Tx 2x0,5
2x0,5
2x0,5
2x0,5
2x0,5
E
A
C
Picture 5: basement section
Pay attention while arising the basement, since the concrete work
cannot impede to stud the fixing screws.
Do not forget wirings! While preparing the concrete basement
keep a duct of the proper dimension to connect the main power
and any possible additional devices.
Drive the wires guide through the right hole of the ground plate and
keep it oriented towards the property.
Make sure ground plate is properly levelled. (Picture 6)
Picture 7: Top view
B
Picture 6:
Basement and ground plate
PROPERTY VIEW
MATRIX - rev. 1.1_09_2020

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents