Tektronix 6 Series Declassification And Security Instructions
Tektronix 6 Series Declassification And Security Instructions

Tektronix 6 Series Declassification And Security Instructions

Mixed signal oscilloscopes

Advertisement

Quick Links

6 Series B Mixed Signal Oscilloscopes
Declassification and Security Instructions
(MSO64B, MSO66B, MSO68B)
Warning: The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified
to do so. Refer to all safety summaries prior to performing service.
Supports Product Firmware V1.28 and above
Register now!
Click the following link to protect your product.
www.tek.com/register
077-1694-00

Advertisement

Table of Contents
loading

Summary of Contents for Tektronix 6 Series

  • Page 1 6 Series B Mixed Signal Oscilloscopes Declassification and Security Instructions (MSO64B, MSO66B, MSO68B) Warning: The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified to do so. Refer to all safety summaries prior to performing service.
  • Page 2 Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material.
  • Page 3: Table Of Contents

    Sanitizing the SSD................................. 9 Troubleshooting ..................................10 How to sanitize a non-functional instrument........................10 Repair charges..................................10 Change log ....................................11 6 Series B MSO Declassification and Security Instructions document change log..............11 6 Series B Mixed Signal Oscilloscopes Declassification and Security Instructions...
  • Page 4: List Of Tables

    List of Tables List of Tables Table 1: Volatile memory................................1 Table 2: Non-user-accessible memory............................2 Table 3: Media and Data export devices ............................7 6 Series B Mixed Signal Oscilloscopes Declassification and Security Instructions...
  • Page 5: Preface

    Instrument Declassification. A term that refers to procedures that must be undertaken before an instrument can be removed from a secure environment. Declassification procedures include memory sanitization and memory removal, and sometimes both. 6 Series B Mixed Signal Oscilloscopes Declassification and Security Instructions...
  • Page 6 Preface 6 Series B Mixed Signal Oscilloscopes Declassification and Security Instructions...
  • Page 7: Clear And Sanitize Procedure

    ≥512 MB graphics operations from the data instrument instrument for a for a minimum of minimum 30 seconds. of 30 seconds. Table continued… 6 Series B Mixed Signal Oscilloscopes Declassification and Security Instructions...
  • Page 8 9 trap door in on the Holds user- the bottom bottom of storable of the data such instrument. instrument. waveforms, measureme nt results, instrument settings. Table continued… 6 Series B Mixed Signal Oscilloscopes Declassification and Security Instructions...
  • Page 9 ≥64 Kbit does not does not configuratio contain user contain user data or data or settings. settings. Clearing Sanitizing would would disable disable instrument instrument functionality. functionality. Table continued… 6 Series B Mixed Signal Oscilloscopes Declassification and Security Instructions...
  • Page 10 Clearing Sanitizing embedded would would controller disable disable firmware. instrument instrument functionality. functionality. Ethernet address is stored in this device. Table continued… 6 Series B Mixed Signal Oscilloscopes Declassification and Security Instructions...
  • Page 11 Clearing Sanitizing would would disable disable instrument instrument functionality. functionality. Table continued… 6 Series B Mixed Signal Oscilloscopes Declassification and Security Instructions...
  • Page 12 ≥0.33 Mbit FPGA FPGA on contain user contain user configuratio data or data or processor settings. settings. carrier Clearing Sanitizing board would would disable disable instrument instrument functionality. functionality. 6 Series B Mixed Signal Oscilloscopes Declassification and Security Instructions...
  • Page 13: Media And Data Export Devices

    Option 6-SEC is installed. Option 6-SEC for a secure instrument Option 6-SEC provides the highest level of instrument security for 6 Series B MSO products. Option 6-SEC features include: • Password protection to enable/disable external communication ports •...
  • Page 14: Overwriting The User Password

    5. Recall the file from the Recall Setup dialog box (File > Recall > Setup tab). For more information on using programmatic commands, refer to your product programmer manual, available at www.tek.com/manuals. 6 Series B Mixed Signal Oscilloscopes Declassification and Security Instructions...
  • Page 15: Clearing Or Sanitizing Ssds

    SSD retain their data and files after running SQE Tests TekSecure. Sanitizing the SSD The instrument does not have any function to sanitize the entire SSD and retain instrument operation. 6 Series B Mixed Signal Oscilloscopes Declassification and Security Instructions...
  • Page 16: Troubleshooting

    How to sanitize a non-functional instrument If your instrument is not functioning, proceed as follows to sanitize the instrument to return to Tektronix for repair: 1. Remove any attached USB flash drives or external USB drives from your oscilloscope. Refer to your company's internal policies regarding handling or disposal of the flash drives.
  • Page 17: Change Log

    Change log Change log 6 Series B MSO Declassification and Security Instructions document change log Document part Revision Change description number date 6 Series B Mixed Signal Oscilloscopes Declassification and Security Instructions...