Electro-Pneumatic Control Installation
10. Locate the laser mounting bracket on top of the
air cylinder air distribution manifold (Ref 21 in
manual 3A5417). Mount the laser in the bracket.
Route the laser cable from the electro-pneumatic
control panel to the laser so that it does not
interfere with system operation.
6
NOTE: The laser emits a dot onto the underside of
NOTE:
NOTE:
the pump support plate. After electro-pneumatic
control panel power up, and before attempting to
run the system, verify that the dot is visible on the
underside of the pump support plate and remains
uninterrupted by hoses and cables during the
entire vertical travel of the ram.