Feature
Ambient temperature
Ambient humidity

1442 Sensor Outer Dimensions and Part Nomenclature

5 mm Sensor
L1 = Unthreaded length
L2 = Case length
L3 = Cable length
Rockwell Automation Publication ICM-UM004C-EN-E - February 2014
Specification
Cable must be in a range of -35...177 °C (-31...350 °F) when devices are
operating.
Connector must be in a range of -35...125 °C
(-31...257 °F) when devices are operating.
ATEX applications must be in a range of -35...80 °C (-31...176 °F) when devices
are operating.
CSA applications must be in a range of -35...85 °C (-31...185 °F) when devices
are operating.
Must be in a range of 30...95% RH (noncondensing) when devices are operating.