Table Of Contents - Data Aire gForce Ultra Installation, Operation And Maintenance Manual

Computer room air conditioner (crac) equipment
Hide thumbs Also See for gForce Ultra:
Table of Contents

Advertisement

1.
INTRODUCTION .......................................................................................................7
1.1
Product Information .............................................................................................7
1.2
Model Identification .............................................................................................8
1.3
Inspection ............................................................................................................8
1.4
Paperwork ...........................................................................................................9
2.
INSTALLATION ......................................................................................................10
2.1
Installation Checklist..........................................................................................10
2.2
Room Considerations ........................................................................................10
2.3
Equipment Handling ..........................................................................................10
2.4
Rigging .............................................................................................................. 11
2.5
Locating the Unit ............................................................................................... 11
2.5.1
Downflow Units ...........................................................................................12
2.5.2
Upflow Units ................................................................................................12
2.6
Storage ..............................................................................................................13
2.7
Piping ................................................................................................................13
2.7.1
Air Cooled Unit Piping.................................................................................14
2.7.2
Discharge Lines ..........................................................................................14
2.7.3
Liquid Lines.................................................................................................15
2.7.4
Recommended Line Sizing, Air Cooled Units .............................................16
2.7.5
Connection Sizes, Air Cooled Units ............................................................17
2.7.6
Field Piping, Remote Condenser Above Evaporator ..................................17
2.7.7
Field Piping, Remote Condenser Below Evaporator ..................................18
2.7.8
Water/Glycol Cooled Unit Piping ................................................................18
2.7.9
Field Piping, Water/Glycol Cooled Units.......................................... .19
2.7.10 Connection Sizes, Water/Glycol Cooled Units................................. ...20
2.7.11 Conection Sizes, Fluid Coolers.........................................................20
2.7.13 Auxiliary Chilled Water/Energy Save Coil Piping..................................21
2.8
Condensate Drain Piping ..................................................................................21

Table of Contents

3

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the gForce Ultra and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF