MANUAL - SOLVENT RECYCLERS - URS1600CE AND URS2000CE

FEATURES AND SPECIFICATIONS

All Uni-ram Solvent Recyclers feature rapid-start direct electric heating of solvent and a short cool-
down time due to high-eff ciency condensers and air cooling with a motor driven fan.
MODEL
VOLTAGE (V) SINGLE PHASE
BRANCH CIRCUIT AMPS
MAX TEMPERATURE SET POINT
TIME TO RECYCLE
TANK CAPACITY
LID GASKET
LINER BAGS
SHIPPING DIMENSIONS (WDH")
*Note on VOLTAGE:
Operating the unit at VOLTAGE lower than 220V
(eg: 208V) may result in reduced performance.
Safety Features:
Certifi ed to IECx and BAS11.0057 Ex db ib IIA T2 Gb , Baseefa11ATEX0118, Ex db h ib IIA T2 Gb.
See the next section, Certif cation,.
Explosion proof construction and intrinsically safe electric circuitry.
Computer controlled with many built-in safety programs including temperature control of all criti-
cal points including tank, condenser and fan motor. Power is cut when the temperature at any of
these points rises above a pre-set level. Operation also terminates when other abnormal conditions
exist (eg: boiling does not start on time or the distillation process takes too long).
Automatic pressure relief lid system prevents pressure in the Distillation Tank from exceeding 0.5
to 1.0 psi. (0.035 to 0.070 kglcm2).
Self Diagnostic error messages are displayed on the Display Panel.
Dual lid cover system.
Compact, enclosed cabinet for safe storage of the Solvent Receiving Container inside the cabinet.
Certif cation
URS2000CE
URS1600CE
220/240*
220/240*
20
200°C
8-10 HOURS
8-10 HOURS
20 US GAL (80L)
16 US GAL (60L)
NEOPRENE
NEOPRENE
YES
47 X 27 X 50
43 X 27 X 50
**Note on MAX TEMPERATURE SET POINT:
If a Liner Bag is used, do not use a SET POINT
greater than 205 °C.
Ex
b
c
d
ib
IIA
T2
Gb
2
Revised 2017-10
20
200°C
YES
EU Explosion atmosphere
symbol
Protection by control of ignition
source
Protection by constructional
safety
Protection by Flame Proof
enclosure
Zone / Measurement Control
Gas Group
Temperature Class 2
Equipment Protection Level,
G=Gas, b=Zone 1