Huawei PTN Series Quick Installation Manual page 4

Transport platform
Hide thumbs Also See for PTN Series:
Table of Contents

Advertisement

OptiX PTN 910E-F Appearance
10
Power supply interface
XGE optical interface
Time interface
NOTE
When the PTN 910E-F operates, switches of two AC
power modules in 1+1 backup mode are enabled and in
ON status, as shown in the right figure.
For details about interfaces on different types of PTN
910E-F routers, see the hardware description.
DCN Interface Distribution
NOTE
By default, DCN is enabled on the first four
interfaces in the four optical interface areas.
Common Requirements for Installing, Laying out, and
Bundling Cables
The space between power cables, network cables, and optical fibers must be greater than 30 mm.
Power cables, network cables, and optical fibers cannot be interleaved but must be routed in parallel or separated with specific stuffs.
When cables are fixed or bound, the interval between two cable ties cannot exceed 40 cm.
When cables are bent, the bending radius is recommended to be greater than 60 mm and cables are not bundled at the turning
points.
The bending radius of optical fibers is no less than 40 mm. Do not pull, press, or squeeze optical fibers during installation.
Gently coil excess optical fibers. Do not forcibly bend the optical fibers.
Do not power on the device when installing and laying out cables.
ESD wrist strap
XGE/GE/FE optical
interface ( These interfaces cannot be switched to work at the rate of 10 Gbit/s )
Equipotential bonding point
2 2
interface
ETH/OAM
FE/GE optical interface
The current status is OFF.
DCN interfaces are
enabled by default.
External clock interface
Boolean interface

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Optix ptn 910e-f

Table of Contents