Troubleshooting; Total Reset Procedure For The Proline® Controller; Watering Cycle Pause Functions - Weathermatic Proline PL800 Owner's Manual

The professional irrigation controller
Hide thumbs Also See for Proline PL800:
Table of Contents

Advertisement

6.0 Troubleshooting

6.1 Total Reset Procedure For The ProLine® controller
A total reset will clear all programming data in the ProLine®
controller. All settings will return to factory defaults.
For all ProLine® models except PL800:
• Turn dial to Advanced Menu.
• While pressing the UP arrow button, use an open paper clip or
ballpoint pen to push in the Reset switch located on the back of
the operating panel. Release the reset button while continuing to
press and hold the UP arrow button.
• Once the display shows CLEARING, release the UP arrow button.
• Reprogram ProLine® controller.
For the PL800:
• Unplug the power supply on the side of the PL800.
• Turn dial to Advanced Menu.
• While continually holding down on the UP arrow button, reapply
the power connection to the PL800.
• The display will read "CLEARING" to verify that the Reset is
complete. Re-enter your controller settings.

6.2 Watering Cycle Pause Functions

ProLine® controllers will "pause" watering cycles in response to
certain sensor readings or program settings in the controller.
Pauses are a normal function of the controller. If a watering pause
occurs, the reason will be shown on the controller's display. The
table below provides a more detailed description of each message.
LANGUAGE
SENSOR
LED Color
LED Color
Red
Green
Red
Green
Red
Green
Red
Green
Orange
Orange
Green
Orange
Green
Orange
Green
Orange
Green
5.0 Advanced Menu
Display
Message
Reason
Controller dial is set
to OFF
RAIN
Rain sensor disks are
wet (SLW Only)
FREEZE
Temperature is 37
degrees F or colder
(SLW Only)
SENS
Sensor tripped at the
SEN terminals
RAIN
Irrigation cancelled
DLY
for additional hours in
SLW DLY (SLW Only)
Omit-
Cycle paused for omit
Time
hours set
SOAK
Zone waiting for soak
time out
ZONE
Waiting for next zone
DLY
valve to open
PAUSE
Waiting for MVP to
turn on or off
18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proline pl1600Proline pl4800