5.0 Advanced Menu
17
the delay or to select a different number of hours (0–99 hours).
Note: The SLW DLY begins after the SLW rain sensor has reset
following a rain event. Accumulation of new water deficits will
not begin until after the SLW DLY has cleared.

5.23 RAIN DLY

The rain delay feature allows user to globally suspend watering
operations for all programs for a selected number of days.
Use UP or DOWN buttons to select 1 to 14 days for watering
suspension. The watering blackout will automatically be cleared
from the SmartLine® controller after the assigned days have
expired and watering will resume at the next available start time.
SMART watering deficits will reset at zero and will not resume
accumulation until the delay has ended.

5.24 SKIP CUR

You can increase the skip circuit threshold here. Some acces-
sory, like pump start relays, In rush currents exceed the factory
setting of 1.0 Amp for SL800 and 1.5A for all other controllers.

5.25 REVIEW

Turn dial to Advanced Menu. Push NEXT button to access review
functions. Use UP/DOWN buttons to select review functions you
wish to view.

5.25.1 SLW

5.25.2.1 LASTCOM
This feature records time elapsed since last successful
communication between the weather station and control
panel.
5.25.2.2 BATTERY
Check the battery status in your wireless weather station
here.

5.25.2 TOTL RUN

TOTL RUN is the total run time for each zone since the date
shown (default date in the SmartLine® controller is January 1,
2000 shown as 01/01/00). You can review TOTL RUN for either
the BASIC or SMART modes. After you select TOTL RUN with
the UP button, use NEXT to view the date when TOTL RUN
accumulation began. Use NEXT again to view the total run times
for each zone.
You can use the NEXT and BACK buttons to move through the
zones. After you go through all the zone positions, use the NEXT
button one more time to take you back to the TOTL RUN screen.

5.25.4 CLR TOTL3

CLR TOTL is used to clear and reset the total run time for each
zone shown in the TOTL RUN menu.
From the CLR TOTL menu, press NEXT and the display will
show KEEP. If you want to clear the TOTL RUN time and reset
the accumulation date, press either the UP or DOWN button to
display CLEAR. With CLEAR showing in the display, either press
NEXT or BACK or turn the dial to complete the clearing and
resetting. This feature will stop accumulations on a zone after
255 hours of cumulative zone run time.