9
When a single zone's Low and High Flow Limits have been
crossed: Only that zone will be shut down.
When the Low and High Flow Limits have been crossed
on two consecutive zones: A Master Valve/Pump Flow
Fault will shut down the entire watering program. (Note: the
program will run again at the next scheduled time or day.)
A master valve is not required for this function. It is only
required that the flow sensor be installed in the line ahead
of the out-of-tolerance problem. However, a Master Valve/
Pump Flow Fault alert will shut down any Master Valve that
is in use.
Reset Running Average: Clicking this button will reset the
Running Averages for all zones to 0.0GPM. New Running
Averages will begin to be recorded.
View Reports: Clicking this button will take you to the
"Reports" page associated with this controller and the
Site "folder" it is within. For more information regarding
"Reports", click the "Help" tab at the top of the page.

5.0 Troubleshooting

Controller
The controller identifies as firmware
not
version other than 3.10 or 3.13. Only 3.10
supported
and higher are compatible and supported.
(Contact distributor to upgrade.)
Could not
The connection timed out. Usually this is
connect
seen when the Aircard is unplugged or
requires a reset (unplug, wait 10 seconds
and plug back in).
http://support.weathermatic.com
Connected,
The Aircard is connected, but it cannot
but no
communicate with the controller. This
response
can happen if the controller door is not
completely closed, or possibly for other
unknown controller-related reasons.
Contacting the Help Desk
If there's a need to contact support, be prepared to provide
the following information:
• Your Name and Contact information
• Site Name
• Which status light is red on the Aircard and/or Error
message received on the SmartLink Network.
• Controller ID – This is found by opening the drop down
menu next to "Additional Controller Info" while in the
controller page.
Troubleshooting 5.0