Download Print this page

Morso 7300 Instructions For Installation And Use Manual page 24

Advertisement

Available languages

Available languages

Minimum distance to combustible material - Morsø 7300
Installation
Normal parallel
Normal parallel
Corner
Minimum distance to combustible material - Morsø 7400
Installation
Normal parallel
Normal parallel
Corner
We recommend that the stove be installed at least 10 - 15 cm from masonry, in order to al-
low heat to circulate and to facilitate the cleaning of the inside and outside of the stove. A
layer of wallpaper on a brick wall is normally viewed as non-flammable material.
The floor
If the stove is installed on a flammable floor, national and local regulations must be observed
with regard to the size of the non-flammable underlying surface that must cover the floor be-
neath the stove. The underlying surface must naturally be able to bear the weight of the stove
and, if applicable, the steel chimney.
Distance to furniture
The minimum clearance to combustible materials in front of the stove is 850 mm. The mini-
mum distance to combustible materials must be observed; furthermore, it should be con-
sidered whether furniture and other items will dry out if placed near the stove.
A wood-burning stove gets hot when it is fired. Caution must therefore be observed, par-
ticularly with regard to children touching the stove.
24
Stove type
Morsø 7300
uninsulated flue
Morsø 7300
insulated flue
Morsø 7300
uninsulated flue
Stove type
Morsø 7400
uninsulated flue
Morsø 7400
insulated flue
Morsø 7400
uninsulated flue
Distance A Distance B
200 mm
400 mm
100 mm
400 mm
-
-
Distance A Distance B
200 mm
450 mm
100 mm
450 mm
-
-
Distance C Distance
front of
stove
-
-
850 mm
350 mm
Distance C Distance
front of
stove
-
-
850 mm
350 mm