Operational Limits - AERMEC VED Technical Manual

Fan coil for horizontal and vertical ducted installation
Hide thumbs Also See for VED:
Table of Contents

Advertisement

OPERATIONAL LIMITS

Maximum water inlet temperature
Maximum recommended water inlet temperature
Maximum operating pressure
Minimum water flow rate (Main coil)
Maximum water flow rate (Main coil)
Minimum water flow rate (Heating Only Coil)
Maximum water flow rate (Heating Only Coil)
External temperature limits (Ta)
Relative humidity limits in the room (R.H.)
Power supply
Protection level
Maximum water inlet temperature
Maximum recommended water inlet temperature
Maximum operating pressure
Minimum water flow rate (Main coil)
Maximum water flow rate (Main coil)
Minimum water flow rate (Heating Only Coil)
Maximum water flow rate (Heating Only Coil)
External temperature limits (Ta)
Relative humidity limits in the room (R.H.)
Power supply
Protection level
The leakage current to earth of several
devices placed under the same circuit
breaker is summed, so attention should
be paid to the calibration of the circuit
Water temperature
In order to prevent air stratification in
the room, and therefore to achieve
improved mixing, it is advisable not
to supply the fan coil with water at a
Minimum average water temperature
If the fan coil is working in continuous
cooling mode in an environment
where the relative humidity is high,
condensate might form on the air
delivery and on the outside of the
device. This condensate might be
deposited on the floor and on any
objects underneath.
To avoid condensate on the external
MINIMUM AVERAGE WATER TEMPERATURE [°C]
Ambient air temperature
with wet bulb
10
IVEDPY 1110 - 4879010_01
VED
VED
breaker and possibly consider the division
of the installation into several circuits
each of which protected by its own circuit
breaker.
temperature over 65°C.
The use of water at high temperatures could
cause squeaking due to the different
thermal expansions of the elements
(plastics and metals), this does not
structure of the apparatus with the fan
in operation, the average temperature
of the water must not be lower than
the limits shown in the table below,
that depend on the thermo-hygrometric
condition of the air in the environment.
The limits mentioned above refer to
operation while the fan is set
to its minimum speed level.
In the event of prolonged fan inactivity
430
440
°C
°C
bar
l/h
300
300
l/h
3000
3000
l/h
-
-
l/h
-
-
°C
230V ( ±10% ) ~ 50 Hz
IP
630
640
°C
°C
bar
l/h
300
300
l/h
4500
4500
l/h
-
-
l/h
-
-
°C
230V ( ±10% ) ~ 50 Hz
IP
Ambient air temperature with dry bulb
21
23
15
3
3
17
3
3
19
3
3
21
6
5
23
-
8
530
540
441
80
65
8
300
300
300
3000
3000
3000
-
-
100
-
-
1500
0° < Ta < 40°
R.H. < 85%
20
730
740
641
80
65
8
300
300
300
4500
4500
4500
-
-
300
-
-
3000
0° < Ta < 40°
R.H. < 85%
20
however cause damage to the unit if the
maximum operating temperature is not
exceeded.
and with cold water passing through
the coil, condensate may form on the
external case of the unit. As a result,
we recommend including the 3-way
valve accessory.
25
27
29
3
3
3
3
3
3
3
3
3
4
3
3
7
6
5
541
300
3000
100
1500
741
300
4500
300
3000
31
3
3
3
3
5