LED indicator
In case of an error the number of blinking light segments
(1)-(2)-(3) indicate the possible cause of the malfunction.
☞ Therefore observe table < Error diagnostics >.
☞ Note:
If the malfunction cannot be repaired and the vehicle
no longer operated, contact your national Meyra-Orto-
pedia sales partner.
Error diagnostics
LED
Cause of error
The battery voltage is too low.
The electrical connection to the left mo-
tor is open-circuit.
The electrical connection to the left mo-
tor is defective (short-circuit).
The electrical connection to the right mo-
tor is open-circuit.
The electrical connection to the right mo-
tor is defective (short-circuit).
The drive disable function is active.
44
3
Fault correction
Check the plug on the operating module and
the battery connections. Charge the batteries.
Check the motor connection cable, motor ca-
ble plug and motor.
Check the motor connection cable, motor ca-
ble plug and motor.
Check the motor connection cable, motor ca-
ble plug and motor.
Check the motor connection cable, motor ca-
ble plug and motor.
The drive disable function is an electronic se-
curity function that prevents the wheelchair
from being driven when a battery charger is
connected.
1
2