SmartCombi™ & ClassicCombi™ Service
Mounting instructions for the WaveClean drain pump 615, 620, 115, 120:
6
Remove screw from the front protection
➢
box [6].
7
Remove nuts [7] and remove pump from
➢
the trap! Note, that water could leak out
of the trap!
Assembling:
The assembly
has to be
➢
exchanged.
Switch on the power and open water tap.
➢
Final function test with the help of the service menu -> WaveClean Test. Close side wall.
➢
Remove protection box.
➢
10
Loosen clamp [8] and pull hose from the pump.
➢
Remove wires from the pump [9].
➢
carried out in reversed order. The gasket [5] (MM211131) between pump and trap should be
9
8
Page 2 of 3
45