Pipe jacking
Table of Contents

Advertisement

!
change the value, change the data to 00400, and then press [ENT] for more than 2s to complete
the setting.;
5) The operating table adjusts the speed about 1500r/min;
6) Install the top iron and the stopper on the main top device so that the two main top oil
cylinders can run synchronously;
7) Enter the "rotation angle correction" interface, operate the main top cylinder retract to
the end, make a mark, the main top cylinder advances for 1 minute to stop, measure the amount
of advancement of the main top cylinder (unit mm), this data is the advancing speed mm/ Min,
fill this data into step 1;
If the two main jacking cylinders cannot be synchronized, the two main jacking cylinders are
added together and divided by two.
the [return to zero];
10) The main jacking cylinder is advanced to the end, measure the actual extension of the
main top (mm), fill in the data column of step 4, and press [to obtain the forward
distance];
11) After the main jacking cylinder is back to the end, press [OK] in step 5.
To understand frequency transmitter operation instructions,
please refer to the TA-MF series SetPro microcomputer-based
frequency isolation transmitter instruction manual.
8) The main jacking cylinder continues to advance, and when the
frequency transmitter data is stable, press [OK] in step 2;
9) The main jacking cylinder retreats to the end, according to step 3 of
59