XCMG XDN450 Operation Manual page 105

Pipe jacking
Table of Contents

Advertisement

!
6.3 Daily storage and protection
When storing the pipe jacking machine, note the following:
1) Before the pipe jacking machine is stored, the entire machine is cleaned. In particular,
the mud pumping system needs to be cleaned to keep the whole machine clean and tidy.
2) It is recommended to place the parts flat on the ground, correcting the cylinder, the main
fuel tank are in a fully contracted state (the whole state and the same transport status, see the
transport dimensions of the drawings);
3) After closing the equipment, inspect the valve block lever, key switch, power switch,
circuit breaker switch, etc.
4) The place where the pipe jacking machine is placed shall be capable of sheltering from
wind and rain, suitable temperature, and away from flammable, explosive and other dangerous
articles.
5) The machine must be covered with a canvas to prevent dust, dust, etc. from damaging
important parts of the machine.
6) Start the pipe jack once every one month or so, and test all the actions of the whole
machine 2-3 times.
7) If the downtime exceeds 2 months, check the cleanliness of the hydraulic oil tank
regularly. If it is not required, the tank must be cleaned and the oil body replaced. And in
accordance with Chapter 4 lubrication maintenance rules, the entire machine maintenance.
Remarks:
Motor storage precautions are detailed in the motor instruction manual.
84