XCMG XDN450 Operation Manual page 49

Pipe jacking
Table of Contents

Advertisement

!
The laser is on the upper side, Y is negative, the nose is lower than
Under the laser, Y is positive, the head is higher than the planned line
The laser is to the right, X is negative, the nose is off the plan line and
!
the planned line and needs to be revised upwards
!
and needs to be revised downwards
!
needs to be corrected to the right
28