nilan CTS700 TOUCH Software Instructions page 38

Hide thumbs Also See for CTS700 TOUCH:
Table of Contents

Advertisement

↳ User program 2
↳ Running time (min)
↳ Program setting
↳ Set point room temperature (°C)
↳ Set point, hot water (°C)
↳ Fan speed level
↳ High priority fan speed
Prioritisation sequence in the control system:
1. Userprogram 2 and 1 with high priority for ventilation
2. High ventilation in connection with cooling
3. Low ventilation in connection with low outdoor air
temperature
4. Low air humidity
5. High air humidity
38
Settings:
Standard setting:
Description:
Settings:
Standard setting:
Description:
Settings:
Standard setting:
Description:
Settings:
Standard setting:
Description:
Settings:
Standard setting:
Description:
Settings:
Standard setting:
Description:
6.
Userprogram 2
7.
Userprogram 1
8.
CO2
9.
Manually set values
10. Weekprogram
0 ↔ 480 minutes
0 minutes
Here it is set how long the program is to run after the
external signal has stopped.
Hence, when connecting a cooker hood, it is
recommended to set it to 0 hours, so the unit returns
to normal operation when the cooker hood is turned
off and the external signal is removed.
Auto/ Night setback/ Fans only
Auto
Here the program is selected which it is wished to run.
5 ↔ 40 °C
20 °C
Here the desired room temperature is set.
10 ↔ 60 °C
36 °C
Here the desired temperature for the domestic hot
water is set.
Level 1/ Level 2/ Level 3/ Level 4
Level 1
Here the desired fan speed level is selected.
On / Off
Off
Here it is selected whether the fan settings should
override all other settings, such as humidity low,
humidity high and winter low.
level (accessory)
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Compact pCompact p polar

Table of Contents