Breathing Technique ..........13 10.1. Application and Operation ........36 10.2. Cleaning and Maintenance ........36 6. The Hot Air Generators VOLCANO DIGIT and VOLCANO CLASSIC ....... 14 11. Attachment of the Balloon to the EASY VALVE 6.1. Unpacking ..............14 with Balloon Adapter resp.
Page 3
Valve Balloon with Mouthpiece Filling Chamber with Cap Compatible with VOLCANO CLASSIC and VOLCANO DIGIT Compatible with VOLCANO CLASSIC and VOLCANO DIGIT 1. P R O D U C T O V E R V I E W V O L C A N O C L A S S I C 1.
European directives and standards. Oakland, CA 94608 Caution! Hot surfaces! All other customers should contact the following address: Never leave Filling Chamber on VOLCANO Hot Air Generator. Storz & Bickel GmbH & Co. KG In Grubenäcker 5-9 Safety recommendations!
VOLCANO. The aromas and fra- The VOLCANO Vaporization System is grances from the plant materials listed inappropriate, incorrect or irrespon- Only use original Storz & Bickel ac- not FDA approved.
5 . FA C T O R S I N F L U E N C I N G VA P O R I Z AT I O N 5 . FA C T O R S I N F L U E N C I N G VA P O R I Z AT I O N The amount of aromas and fragrances temperature, then the vaporization It is not necessary to fill the Valve Bal-...
If there are any faults in the electronics facturer cannot be held responsible. the accessories from the box. Imme- of VOLCANO DIGIT, you can per-form diately after unpacking check whether a reset by pulling out the power plug the Hot Air Generator, the accessories, and plugging it again after waiting for 6.3.
In this case, Do not try to remedy the defect your- send the VOLCANO Hot Air Generator to our Service self. Contact our Service Center di- Center. rectly.
Button Button lower, green display shows the desired by switching on the air pump. the VOLCANO DIGIT on a flat set temperature. The heating process and stable surface. 30 minutes after the last time is completed when the set value is...
Hot Air Genera- in a perfect condition. Only connect tor and allow it to lock in place. Switch the VOLCANO CLASSIC to a properly on the air pump. To do so, press the installed (grounded) socket.
Page 12
Never leave the Filling Chamber on top hold the Filling Chamber Cap at the opens and the vapors can be inhaled of the hot air outlet of the VOLCANO textured grip. from the Valve Balloon. As soon as you as long as the heater is on, except remove the pressure from the Mouth- when filling the Valve Balloon.
9. E A S Y VA LV E 9. E A S Y VA LV E Filling Chamber with Filling Chamber Push the Cap Cylinder downwards out of the Cap Housing. At the same time the Cap Ring will be stripped off. Please allow the Filling Chamber and the Cap to cool down before disassem- bling them.
9. E A S Y VA LV E 9. E A S Y VA LV E Disassembling the Filling Chamber Assembling the Filling Chamber 9.3. Accessories Filling the Filling Chamber Reducer with aromatic Oils Push the lower Screen or the Drip Pad Push the Filling Chamber Cylinder 9.3.1.
9. E A S Y VA LV E 9. E A S Y VA LV E 9.3.2. Dosing Capsules and Grind the plant material and fill the Please make sure to not over- Magazine Dosing Capsule by using the Magazine fill the Drip Pad.
9. E A S Y VA LV E 9. E A S Y VA LV E Inserting the Dosing Capsules 9.3.3. Filling Set for 40 Dosing Capsules First, the Filling Chamber Reducer, that is available as an accessory as well, The Filling Set for 40 Dosing Capsules is to be inserted instead of the Filling was developed to fill a larger quantity...
10. S O L I D VA LV E 10. S O L I D VA LV E approx. 5 sec 10.1. Application and Operation The Balloon Material must be kept out of the reach of chil- dren as it is a potential source of danger.
Page 18
Do not leave the Filling Chamber on top lips and press them lightly against the loss of vapor. It is important to watch of the hot air outlet of the VOLCANO Mouthpiece. By doing so, the Valve the vapor density in the Valve Balloon when “HEAT”...
10. S O L I D VA LV E 10. S O L I D VA LV E 10.2. Cleaning and Maintenance The Mouthpiece, Valve and Filling Disassembling the Mouthpiece Chamber are easily disassembled Pull off the Lip Piece from the Mouth- Mouthpiece, Valve and Filling within seconds for cleaning.
Page 20
10. S O L I D VA LV E 10. S O L I D VA LV E Disassembling the Valve Remove the Valve Cap and Valve Ring. Disassembling the Filling Chamber Disassembling the Filling Chamber Pull out the Valve Cylinder along with Insert Undo the Slipring and remove the The lower Screen will be pushed out...
B A L L O O N A D A P T E R R E S P. S O L I D VA LV E Filling Chamber Housing and Filling As an alternative to the VOLCANO Bal- Chamber Cylinder can be screwed off loon, use an odor-free, heat-resistant now.
11. AT TA C H M E N T T O T H E E A S Y VA LV E W I T H 12 . D R I P PA D B A L L O O N A D A P T E R R E S P. S O L I D VA LV E Adjust the folds equally around the The Drip Pad is used to vaporize the 12.2.
Subject to technical changes. the liquid is distributed more evenly made of stainless steel, it can be used the bottom side of the VOLCANO Hot Patents and designs: around the stainless steel wire of the again and again if it is cleaned well.
In addition, we we offer competent repair service to er 5-9, 78532 Tuttlingen. American guarantee that our product VOLCANO our customers. We will promptly repair and Canadian customers should di- will be free from defects for a period of any defective products made by us rect warranty claims to Storz &...
Page 25
S T O R Z & B I C K E L G M B H & C O. K G In Grubenäcker 5-9 · 78532 Tuttlingen/Germany...
Need help?
Do you have a question about the Volcano and is the answer not in the manual?
Questions and answers