Steps
4. Remove fan motor
1
Remove the nuts fixing the blade and then
remove the axial flow blade.
2
Remove the 4 tappin g screw s fixing the
motor; disconnect the leading wire insert of
the motor and then remove the moto r.
Remove the 2 tappin g scre ws fixing the
motor support and then pull the motor
support up wa rds to remove it.
5. Remov e electric box
Remove the scre ws fixing the electric box
sub-assy; loosen the wi re bundle; pull out
the wi ring terminals and then pull the
electric box upwards to remove it.
92
Procedure
axial flow blade
motor support
motor
electric box