Download Print this page

Emerson FB1100 Replacement Manual page 16

Flow computer termination board field
Hide thumbs Also See for FB1100:

Advertisement

FB1100/FB1200 Flow Computer Termination Board Field Replacement Guide
D301820X012
November 2020
13.
14.
15.
14
You can now plug your new terminal blocks back into the termination board, leaving TB1
last for when you want to restore power.
Carefully align the end cap threads with the threads of the enclosure and replace the rear
end cap. Screw the end cap clockwise (eight full turns) until it is tightly sealed to the
enclosure. Endcaps must have at least 8 full threads engaged upon reassembly.
Note
If you need more leverage place a long screwdriver or other appropriate tool across the two
notches in the cover to act as a pry bar.
If applicable, tighten the retaining clamp using the screw and washer onto the end cap
using a 3mm hexagonal wrench. When tightening, torque to 10 to 12 in-lbs (1.1 to 1.4
N-m).

Advertisement

loading

This manual is also suitable for:

Fb1200