Summary of Contents for Cosel ADA600F

  • Page 1 (217) 352-9330 | Click HERE Find the Cosel ADA1000F-30 at our website:...
  • Page 2: Basic Characteristics Data

    Single Double Series Parallel input fuse protection Material [kHz] operation operation sided sided Active filter ADA600F 250V 12A FR-4 ( Peak 7.0 ) Forward converter Active filter ADA750F 250V 20A FR-4 ( Peak11.8 ) Forward converter Active filter ADA1000F 250V 25A FR-4 ( Peak18.2 )
  • Page 3 Instruction Manual AC-DC Power Supplies Enclosed Type Function ADA-10 ADA-10 Input voltage range ADA-10 Inrush current limiting ADA-10 Overcurrent protection ADA-10 Peakcurrent protection ADA-10 Thermal protection ADA-10 Overvoltage protection ADA-10 Output voltage adjustment range ADA-10 Isolation Assembling and Installation Method ADA-10 ADA-10 Installation method...
  • Page 4: Assembling And Installation Method

    Instruction Manual AC-DC Power Supplies Enclosed Type 1.6 Overvoltage protection 1 Function ¡Overvoltage protection is built in. When the overvoltage protec- tion activates, shut off input, wait for at least 3 to 4 minutes, and 1.1 Input voltage range recycle to recover output voltage(*). *The recovery time varies depending on input voltage.
  • Page 5 3The confi rmation of point A and B in unnecessary when optional - V NL fun unit is used. Refer to 5.Option. 20mm min *The derating curve at forced air is common in ADA600F to ADA1000F. Fixed screw (4 pcs.) Fixed screw (4 pcs.)
  • Page 6: Series Operation And Parallel Operation

    Load current (A) parallel operation current per unit Fig.2.4 Load current conversion graph (ADA600F-24) When the number of units in parallel operation increases, input current increases at the same time. Adequate wiring design for input circuitry is required, such as circuit pattern, wiring and cur- rent capacity for equipment.
  • Page 7 Peak output power Pp [W] the master, and turn the potentiometer of the other, “slave” power Fig.4.1 Relation between Peak power and Duty (ADA600F) supplies, clockwise to the end. Then use the potentiometer of the mater to adjust output voltage.
  • Page 8 Instruction Manual AC-DC Power Supplies Enclosed Type Voltage adjust Table.5.1 Low leakage type Name plate Leakage current (230 VAC) 0.5mA max 0.15mA max Conducted Noise Class A Not available Ripple Noise 1.5 times standard 2.0 times standard ¿-F (It is not possible combine with option -J) -Option -F means fan unit is attached to standard model.
  • Page 9 Instruction Manual AC-DC Power Supplies Enclosed Type CN3* Table 5.2 Explanation of alarms RC (+) Alarm Output of alarm I=20mA max External Power When line voltage is abnor- Open collector method Source mal (low input voltage out of Good : Low RC (-) range), the alarm outputs from (0 - 0.8V, 1mA max)
  • Page 10 (your system). *Parallel operation cannot be done with standard model. - The following electric specifi cations are different from standard model. Output Voltage(V) ADA600F Load ADA750F Regulation 240 max 300 max...