Ac-dc power supplies open frame/ enclosed type (7 pages)
Summary of Contents for Cosel AME600F
Page 1
Parallel Material [kHz] circuit sided sided operation operation Active filter Input module of Relay FR-4 AME600F Half-bridge converter Active filter Input module of Relay FR-4 AME1200F Half-bridge converter Output module of Buck converter FR-4 ○ Series operation is possible with the same output modules.
Instruction Manual AC-DC Power Supplies Configurable Type Terminal Blocks AME-8 Configuration - Model Name Construction AME-10 Series / Parallel operation in Modular power supply AME-11 Series operation AME-11 Functions AME-11 Input voltage range AME-11 Inrush current limiting AME-11 Overcurrent protection AME-11 Thermal protection AME-11...
Table 1.1 Pin configuration and function of CN1 1 Terminal Blocks Ground Pin No. Function level : Auxiliary power AUXG : Auxiliary power ground ¿ AME600F AUXG : Global inhibit AUXG : Auxiliary power ground ① : Global inhibit ④ ②...
Page 4
Instruction Manual AC-DC Power Supplies Configurable Type ¿ Output module ③ ④ ⑤ ② ① Module : A-D 1-Output 2+Output 3CN3 (connector) 4LED (DC_OK) 5Potentiometer to adjust output voltage Table 1.4 Pin configuration and function of CN3 (Applying module:A-D) Ground Pin No.
Instruction Manual AC-DC Power Supplies Configurable Type <Order Name example> 2 Configuration - Model AM12 - O D C C B A - O O O O O O O : Alphanumeral O : management number (6digits) Name Construction ¿ Note (1) Please select the output module codes from the specifications The AME series has Order Name which is used for the ordering to correspond with required voltage and current.
Instruction Manual AC-DC Power Supplies Configurable Type 3 Series / Parallel operation 4 Functions in Modular power supply 4.1 Input voltage range ¡ The input voltage range is from 85 VAC to 264 VAC. 3.1 Series operation The rated input voltage range for the safety approvals is from 100VAC to 240VAC (50/60Hz).
Instruction Manual AC-DC Power Supplies Configurable Type 4.5 Overvoltage protection 4.8 Remote ON/OFF(RC) ¡ When the overvoltage protection activates, outputs on all output ¡ Each output module have remote ON/OFF functions. The output modules will shut down. voltage can be turned on/off by the signal to RC terminal in CN3 When either one of the following actions is taken, the output will on each modules.
Instruction Manual AC-DC Power Supplies Configurable Type 4.11 Alarm 4 The built-in fans will stop when all output modules are turned off by the Global inhibit function. ¡ The unit has two typs of alarm below. Table 4.3 is the detail of the 5 AUX is available even when outputs are turned off by Global alarm.
Instruction Manual AC-DC Power Supplies Configurable Type 4.12 Auxiliary power (AUX) 5 Assembling and ¡ The unit has the auxiliary power (AUX: 5V1A) in CN1 to provide Installation Method for the remote ON/OFF and external circuits. ¡ When the Global inhibit function activates, the following derating for the AUX is required.
170VAC Ta = 40C 10 years 4 years mounting Ta = 40C or less 10 years 4 years 170 to direction 264VAC Ta = 50C 7 years 2 years Input voltage [VAC] Fig.5.6 Derating curve for input voltage (AME600F) AME-15...
Page 11
Ambient temperature[ C ] Fig.5.8 Life expectancy of fan ¡ Warranty term Warranty is as follows and shall be 5 years maximum. Warranty does not apply if used outside of derating specifications. Table.5.4 Warranty term (AME600F) Warranty term Mounting Input Average ambient...
Need help?
Do you have a question about the AME600F and is the answer not in the manual?
Questions and answers