Ac-dc power supplies open frame/enclosed type (9 pages)
Summary of Contents for Cosel KL Series
Page 1
AC-DC Power Supplies DIN Rail Type Power World wide Safety Inrush Factor Approvals current Correction limiting KL-series Feature For DIN (35mm) rail products Complies with FCC-B, CISPR22-B, EN55011-B, EN55022-B, Wide operating ambient temperature range VCCI-B I/O terminal has 2 types, Euro Style and Barrier Blocks Style EMS Compliance Built in overcurrent protection, overvoltage protection circuits : EN61204-3, EN61000-6-2...
Page 2
Ordering information AC-DC Power Supplies DIN Rail Type KLEA/KLNA120F -OO -O 1 Series name Example recommended EMI/EMC filter KLE : Euro Style I/O Terminals NAC-04-472-D KLN : Barrier Blocks Style I/O Terminals 2 Single output 3 Output wattage 4 Universal input UL508 5 Output voltage 6 Option...
Page 3
KL series Block diagram FUSE 250V 4A INRUSH NOISE CURRENT AC IN 85 264V RECTIFIER FILTER LIMIT BOOSTER CURRENT INDUCTOR SENSING TRANSFORMER RECTIFIER RECTIFIER INVERTER DC OUT FILTER FILTER INVERTER CURRENT SENSING Photocoupler CONTROL Photocoupler OVER VOLTAGE CONTROL PROTECTION External view <KLEA120F(Euro Style I/O Terminals)>...
Page 4
Ordering information AC-DC Power Supplies DIN Rail Type KLEA/KLNA240F -OO -O 1 Series name Example recommended EMI/EMC filter KLE : Euro Style I/O Terminals NAC-06-472-D KLN : Barrier Blocks Style I/O Terminals 2 Single output 3 Output wattage 4 Universal input UL508 5 Output voltage 6 Option...
Page 5
KL series Block diagram FUSE 250V 8A INRUSH NOISE CURRENT AC IN 85 264V RECTIFIER FILTER LIMIT BOOSTER CURRENT INDUCTOR SENSING TRANSFORMER RECTIFIER RECTIFIER INVERTER DC OUT FILTER FILTER INVERTER CURRENT SENSING Photocoupler CONTROL Photocoupler OVER VOLTAGE CONTROL CONTROL PROTECTION External view <KLEA240F(Euro Style I/O Terminals)>...
Page 6
KL-series Terminal Blocks ¿ KLEA120F ¿ KLNA120F ¿ KLEA240F ¿ KLNA240F Terminal Terminal Function Number Name Protective earth Terminal AC (N) Input Terminals AC (L) +VOUT +Output Terminals -VOUT -Output Terminals DC_OK LED for output voltage confirmation Adjustment of output voltage INPUT OUTPUT OUTPUT INPUT Assembling and Installation Method DIN rail...
Page 7
KL-series Assembling and Installation Method ¡ Shown below the notes about installation clearance of a unit. Convection 25mm or more 1 Installation clearance at above and below the unit. Please have clearance of at least 25mm above and below the unit to avoid heat accumulation.
Page 8
-30 -20 -10 Ambient Temperature [C] Ambient Temperature [C] Instruction Manual ◆ It is neccessary to read the “Instruction Manual” and “Before using our product” before you use our product. Instruction Manual https://en.cosel.co.jp/product/powersupply/KL/ Before using our product https://en.cosel.co.jp/technical/caution/index.html NOTICE Basic Characteristics Data Inrush...
This manual is also suitable for:
Klea120f-24Klna120f-24Klea240f-24Klna240f-24Klea120f-48Klna120f-48...
Show all
Need help?
Do you have a question about the KL Series and is the answer not in the manual?
Questions and answers